Operating manual BDC3140 DBP/LPP
HEPA filter replacement
Take care not to raise dust when this operation is
carried out. Wear a P3 mask and other protective
clothing plus protective gloves (DPI) suited to the
hazardous nature of the dust collected, refer to the
laws in force.
Do not use the absolute filter again after having
removed it from the vacuum cleaner.
1.
Vacuum cap
Locking lever
2.
3.
Safety bolt
4.
Absolute filter lock ring
Absolute filter disc
5.
6.
Absolute filter
Before proceeding with these operations, turn the vacuum
cleaner off and disconnect the plug from the power socket.
Unlock the safety bolt (3).
■
Use the lever (2) to release the cap (1) then pull it up
■
and out of the vacuum cleaner.
■
Unscrew ring (4).
Pull out disc (5) and absolute filter (6).
■
■
Place absolute filter (6) in a plastic bag, close the bag
hermetically and dispose of the filter in accordance with
the laws in force.
Insert a new filter (6) with the same filtering
■
characteristics as the removed one.
Lock the absolute filter with disc (5) and tighten ring (4).
■
Insert the cap (1) again.
■
■
Fix the cap in place with the lever (2) and lock the
safety bolt (3) again.
Motor cooling fan inspection and
cleaning
GB
Periodically clean the motor cooling fan to prevent the motor
from overheating, especially if the vacuum cleaner is used in
a dusty place.
Tightness inspection
1.
Suction connecting hose
2.
Hose
Hoses check
■
Make sure that the suction connecting hose (1) is in a
good condition and correctly fixed.
If the hose is damaged, broken or badly connected to
the unions, it must be replaced.
When sticky materials are treated, check for possible
clogging along the hose (2), in the inlet and on the
baffle plate inside the filtering chamber.
Scrape the inlet from the outside and remove the
deposited waste as indicated in the figure.
WARNING!
WARNING!
Figure 11
Figure 12
Figure 13
Seal
1.
2.
Screws
3.
Filtering chamber
■
Filtering chamber tightness check
If the gasket (1) between the container and the filtering
chamber (3) fails to guarantee tightness:
▪
Loosen the four screws (2) that lock the filtering
chamber (3) against the vacuum cleaner structure.
Allow the filtering chamber (3) to lower down and
▪
tighten the screws (2) once it has reached the
tightness position.
The gasket (1) must be replaced if it is torn, cut, etc.
Disposing of the vacuum cleaner
Figure 14
Dispose of the vacuum cleaner in compliance with the laws
in force.
■
Proper disposal (electric and electronic waste).
(Applicable in the European Union and in
countries providing a separate collection system)
The above symbol (Fig. 14), which is present on the product
or in its documentation, indicates that the product cannot be
disposed of together with other domestic waste at the end of
its life cycle.
To prevent damage to the environment or health caused by
improper waste disposal, please separate this product from
other waste and recycle it responsibly in order to support the
sustainable reutilisation of material resources.
This product can not be disposed of together with other
commercial waste.
Wiring diagrams
Figure 15 - 16
Item
Part
230V/60Hz 400V/50Hz 440/60Hz
Q1
Main switch
Circuit
Z8 39535
Q2
breaker
Z8 39726
Z8 39102
KM1
Contactor
Z8 39838
TS2
Cyclic timer
10/12
Code of the model
Z8 39989
Z8 39916
Z8 39014
Z8 39726
Z8 39726
Z8 39281
Z8 391105
Z8 391107