READING THESE INSTRUCTIONS IS IMPORTANT FOR PERSONAL SAFETY. READ THE FOLLOWING REMARKS CAREFULLY BEFORE
PROCEEDING WITH THE INSTALLATION. PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
ORIGINAL INSTRUCTION MANUAL. NOT READING THESE IMPORTANT INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING ORDER
OF THE SYSTEM AND CREATE DANGER SITUATIONS FOR THE USERS OF THE SYSTEM. SAVE THESE INSTRUCTIONS FOR FUTURE USE.
• These instructions are aimed at professionally qualified 'INSTALLERS
OF ELECTRICAL EQUIPMENT' and must respect the local standards
and regulations in force.
All materials used must be approved and must suit the environment
in which the installation is situated and all maintenance operations
must be carried out by professionally qualified technicians.
• This appliance must be used exclusively for the purpose for which it
has been made. 'i.e. for the automation of hinged gates' with one
or two gate leaves.
CAUTION! Mechanical stop buffers must be installed in both
the closing and opening positions.
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the installer to make sure that the following
public safety conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from
the main road to eliminate possible traffic disruptions.
2) The motor must be installed on the inside of the property and not on
the public side of the gate. The gates must not open onto a public
area.
3) The gate operator is designed for use on gates through which vehicles
are passing. Pedestrians should use a separate entrance.
4) The controls must be installed at a height between 1,5 and 1,8 m and
in a location not accessible to children. Controls installed externally
must be protected by a safety device inhibiting unauthorised use.
5) At least two warning signs (similar to the example
on the right) should be placed, where they can be
easily seen by the public, in the area of the system
of automatic operation. One inside the property
and one on the public side of the installation. These
signs must be indelible and not hidden by any objects (such as tree
branches, decorative fencing etc.).
6) Make sure that the end-user is aware that children and/or pets must
not be allowed to play within the area of a gate installation. If possible
include this in the warning signs.
7) Whenever a fully open gate leaf comes within at 500 mm of a fixed
structure the space must be protected by an anticrush buffer.
8) You are advised to protect the system's lateral access points with
pairs of (FS) photocells connected to the stop input, see installation
example, component 14 on page 2.
9) If you have any questions about the safety of the gate operating
system, do not install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
BL1924ASW is suitable for the automation of hinged gates with one
or two gate leaves, max. length 2 m, max. weight 150 kg.
• Drive motor maximum 28 Vdc with an incorporated encoder
• Permanently lubricated double reduction unit mounted on a cast
iron stator with a never ending screw.
• Irreversible reduction unit with a key-operated manual release
mechanism.
• Carter in shock-proof plastic.
• Motor support base in zinc-plated steel
• Articulated operator arm in spray painted cast aluminium.
ATTENTION! IMPORTANT SAFETY INSTRUCTIONS
AUTOMATIC OPENING
APERTURA AUTOMATICA
FERMETURE AUTOMATISÉE
AUTOMATISCHER ÖFFNUNG
Installation company:
Serial number:
Product model:
Installation date:
®
Weight in kg:
riello elettronica group
ZVE: 572 - Mod: 04-09-2017
USER INSTRUCTIONS
Attention! Only for EU customers - WEEE marking.
This symbol indicates that once the products life-span has
expired it must be disposed of separately from other rubbish.
The user is therefore obliged to either take the product to a
suitable differential collection site for electronic and electrical
goods or to send it back to the manufacturer if the intention
is to replace it with a new equivalent version of the same
product.
Suitable differential collection, environmental friendly treatment and
disposal contributes to avoiding negative effects on the ambient and
consequently health as well as favouring the recycling of materials.
Illicitly disposing of this product by the owner is punishable by law and
will be dealt with according to the laws and standards of the individual
member nation.
During the opening/closing manoeuvre check for correct operation and
activate the emergency stop button in case of danger. During blackouts
the gate can be released and manually manoeuvred using the supplied
release key (see manual release page 12).
INSTALLATION INSTRUCTIONS
The minimum controls which may be installed are OPEN-STOP-
CLOSE, these controls must be installed in a location not accessible
to children and outside the opening range of the gate.
Before starting the installation of the system check that the structure
which is to be automated is in good working order and respects the
local standards and regulations in force.
To this end make sure that the gate is sufficiently rigid (if necessary
reinforce the structure) and that it pivots easily.
You are advised to grease all the moving parts using lubricants which
maintain unaltered friction characteristics over a period of time and
are suitable for temperatures of -20 to +70°C.
• Check the safety measures between the fixed and moving parts:
- a minimum space of 30 mm must always be left along the entire
distance between the gate and the support column measured
throughout the entire opening angle of the gate.
- make sure that the space between the bottom of the gate and the
pavement never exceeds 30 mm throughout the entire opening
angle of the gate.
• The surface of the gate must not feature openings which allow a
person's hand or foot to pass through.
• Check the exact positioning of the pivots, and their good working
order (the upper and lower hinges/pivots must be aligned on the
same axis).
• Work out the run of the cables according to the command and
control devices fitted and make sure the system conforms to the
local standard and regulations in force (see installation example).
• Check that the appliance is suitable for the size, weight and duty
cycle of the gate to which it is to be applied (see duty cycle on page
20).
ASSEMBLY PROCEDURE
The unit may be positioned to the right or to the left of the passageway.
• Move the gate/s to the closed position.
• Choose the value "A" (fig. 4) according to the required opening angle
and work out (depending on the structural characteristics of the gate) at
what height the front bracket will be fitted to the gate. Once the position
has been established, fasten down the motor support plate using four
M8 screws and steel Ø14 rawlplugs. Make sure that the support bracket
"D" (fig. 7) is in square.
11