ProFlow PF-SOF1-SIM Instrucciones De Instalación página 16

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 91
only for PF-SOF1-PRL & PF-SOF1,5-PRL
The 2 Simplex systems, that make up a Duplex system,
must be programmed individually; the program does NOT
necessarily have to be the same on the 2 Simplex systems!
1. Press the scroll
button and hold it for 6 sec until the
display shows:
System Check
2. Within 10 sec, press the up
show:
Units:Metric
Press the up
or down
measure (Metric or US).
3. Press the scroll
button again; the display will show:
MaintInt: 24mths
Press the up
or down
maintenance reminder function by setting the
maintenance interval, or deactivate the maintenance
reminder function.
4. Press the scroll
button again; the display will show:
ExCap:5.5°f M3/L
Press the up
or down
exchange capacity per litre of resin.
5. Press the scroll
button again; the display will show:
Age corr.:
Press the up
or down
correction factor (%/year) to compensate for capacity
loss of the resin due to aging.
6. Press the scroll
button again; the display will show:
Resin:XXX liters
Press the up
or down
of resin.
7. Press the scroll
button again; the display will show:
Override: 7 days
Press the up
or down
of days between regenerations.
8. Press the scroll
button again; the display will show:
Cycle 1:
Press the up
or down
of the regeneration cycle.
Press the scroll
button again to advance to the next
regeneration cycle.
EN - English
ELECTRONIC CONTROL PANEL
button; the display will
button to set the units of
button to activate the
button to set the
2.0%
button to set the age
button to set the volume
button to set the number
XX min
button to set the length
Cycle 1
Cycle 2
Cycle 3
Cycle 4
9. Press the scroll
Regen:Immediate
Press the up
regeneration mode:
Immediate: when the remaining capacity equals
0, an immediate regeneration is started.
Note: Delayed manual regeneration is not
available when this regeneration mode is
selected.
 Dlyd/Immd: when the remaining capacity equals
the reserve capacity, a delayed regeneration at
the programmed time of regeneration is started;
however when the remaining capacity equals 0
before the programmed time of regeneration is
reached, an immediate regeneration is started.
 Delayed: when the remaining capacity equals the
reserve capacity, a delayed regeneration at the
programmed time of regeneration is started.
10. Press the scroll
(only when the regeneration mode is set to 'Delayed' or
'Dlyd/Immd'):
Regen @
Press the up
regeneration.
11. Press the scroll
(only when the regeneration mode is set to 'Delayed' or
'Dlyd/Immd'):
Rsrv
Press the up
capacity:
 Variable: the reserve capacity is calculated
automatically, based on the registered daily water
usage.
 Fxd: press the scroll
up
capacity to a fixed amount.
12. Press the scroll
Exit
Press the up
program into
programming level.
13. Repeat steps 1-12 for both Simplex systems.
Page 16
Backwash
Brine draw/slow rinse
Fast rinse/brine tank refill (PF-SOF1)
Fast rinse (PF-SOF1,5)
Brine tank refill (PF-SOF1,5)
button again; the display will show:
or down
button to set the
button again; the display will show
2:00
or down
button to set the time of
button again; the display will show
Variable
or down
button to set the reserve
button again and press the
or down
button to set the reserve
button again; the display will show:
or down
button to save the
the
NOVRAM® and
exit the

Publicidad

Tabla de contenido
loading

Tabla de contenido