Cable locator
3.2.2 Finding fuses
In a multi-dwelling building, use the L and N terminals of a household outlet to
send the emitter signals (as shown in Fig. 3-2-2) and set the transmit power of
the unit to a appropriate level.
Preconditions:
* Disconnect all air switches from the distribution box.
* Connect the emitter according to Fig. 3-2-2.
Caution!
1. Identification and positioning of fuses are highly influenced by the wiring
situation in the distribution panel. To search for fuses as precisely as possible,
you must open or remove the switch panel cover, and search for the fuse
feeder.
2. In the search process, the fuse with the strongest and most stable signals
will be the target to be searched for. Due to signal coupling, the detector can
detect signals from other fuses, but the strength of those signals will be
relatively weak.
Recommendations
1. For detection, it is better to put the detector tip at the inlet of the fuse box to
get the best detection result.
2. Adjust the transmitting power of the emitter to suit different detection radii.
Select manual mode on the receiver to set a suitable receive sensitivity to
precisely locate the circuit.
31