INSTALLATION & PREPARATION
NOZZLE REVIEW:
Various nozzles may be quick-connected into the end of the wand to
change the spray pattern. When using Quick Connects (Q.C.), be certain
the connection is securely locked. If not, the high pressure water may
shoot the nozzle from the wand, causing severe injury or serious dam-
age. To determine spray fan, refer to the actual number stamped on the
nozzle. The first two digits indicate the spray fan in degrees, i.e.; 15=15°,
25=25°, 65=65°.
1. The 15° nozzle (YELLOW): This is a chiseling nozzle. The spray should
be directed at a 45° angle to the surface and used like a scraper to
remove paint, grease and dirt. Uses: Surface preparation (removing
mildew stains and paint chips).
2. The 25° nozzle (GREEN): This is a flushing nozzle. This pattern is best
suited for flushing dirt, mud, and grime. Uses: Wet sweeping leaves from
walks, curbs and driveways, cleaning stable floors, washing swimming
pool bottoms, degreasing engines.
3. The 65° nozzle (BLACK): This is a low pressure detergent application
nozzle. This broad spray pattern distributes solution over vast areas
under low pressure. Uses: Detergent application, misting or rinsing.
NOZZLE CONNECTION:
1. Be certain the trigger gun is locked in the "OFF" position. See WARNING
at right.
2. The nozzle assembly should be disconnected from the gun assembly
at this time by retracting the locking ring on the quick-connect fitting to
remove the nozzle.
THERMAL RELIEF VALVE:
To ensure the water temperature does not exceed acceptable levels,
never allow the pressure washer to operate in the bypass mode (with the
unit running and the trigger gun closed) for more than three minutes.
Your unit is provided with a thermal relief valve. The thermal relief valve
will be located opposite the water inlet on your pump. The thermal relief
valve may begin to open and release water if the water temperature in the
pump has exceeded 140°F. This will allow fresh, cool water to enter the
system.
Operator's Manual
QUICK-CONNECTION
WARNING RISK OF
INJECTION CAUSING
SEVERE INJURY!
-NEVER LOOK DIRECTLY AT THE
NOZZLE ORIFICE UNLESS IT IS
DISCONNECTED FROM THE
GUN/WAND ASSEMBLY!
CONNECTION OF Q.C. NOZZLES
QUICK-CONNECT (Q.C.)
WARNING RISK OF
SEVERE INJURY!
THE TRIGGER GUN SHOULD
ALWAYS BE LOCKED IN THE
OFF POSITION WHEN NOT IN
USE!
11

Publicidad

loading

Este manual también es adecuado para:

The chore master cv-2600-4mmcThe chore master cv-2600-3mmc