Descargar Imprimir esta página

VALBERG TSH 90 T X 962C Manual Del Usuario página 7

Ocultar thumbs Ver también para TSH 90 T X 962C:

Publicidad

Idiomas disponibles

Idiomas disponibles

B
Using the appliance
Intended use
The appliance has been designed for use in extraction mode (evacuation of air outside) and
filtration mode (air returning inside).
Installation
CAUTION
Make sure that your product is installed in accordance with
the instruction manual to reduce its overall environmental
impact of the cooking process (e.g. energy consumption).
Keep the area in which the appliance is used well ventilated.
Keep the extraction conduit straight and make sure that it
is as short as possible.
1
The minimum distance between the support surface for cooking vessels on the cooking
device and the lowest part of the extraction hood must be 65 cm.
CAUTION
• Specialist staff must be called upon for assembly and
electrical connections.
• Use protective gloves when carrying out assembly
operations.
Power supply connection
Check that the socket is still accessible after the appliance has been installed. If the
appliance comes with a cable without a plug, you will need to add a multiple-pole switch
between the mains and the appliance with a contact opening distance of at least 3 mm,
which is sized for the load and compliant with the applicable regulations.
Connecting the appliance to the power circuit:
BROWN
=
L line
BLUE
=
N neutral
• If you need to use a connector pipe consisting of at least two parts, the upper part must be
outside the lower one. Do not connect the outlet pipe from the hood to a conduit containing warm
air or which is used to discharge steam from appliances supplied with energy other than electricity.
10
EN
B
Using the appliance
An air discharge opening must be provided for extractor hoods.
We recommend using an air discharge pipe with the same diameter as the air outlet opening.
Smaller diameters could reduce the product performance and increase the noise level.
Extractor version
2
With this type of installation, the appliance releases vapours outside through an outer
wall or an existing pipe.
Recycling version
Contact your supplier to obtain active carbon filters to transform the extractor hood into a
recycling hood.
Installing the active carbon filter (cassette)
Check that the diameter of the active carbon filter corresponds the outlet diameter.
If necessary, remove the pre-installed diameter adapter.
Position the active carbon filter on the outlet and attach it in place by turning anticlockwise.
Installing the active carbon filter (cut-out)
The metal filter has to be removed before the active carbon filter is installed.
To open the metal filter, press on the locking device and pull the filter downwards.
Place the precut filter on top of the metal filter. Hold in position using the metal rods
(supplied according to the model).
Replace the metal filter in its original position.
3
Make three 8 mm holes in the wall in the required position and assemble the wall bracket.
Attach using the screws and dowels provided.
4
Lift the hood and attach it to the wall bracket.
5
Connect the discharge duct
6
Slide the upper part of the chimney inside the lower part and then pull the upper part
upwards to the required height.
7
Connect the two parts together once the chimney has been positioned at the correct height.
11
EN

Publicidad

loading

Este manual también es adecuado para:

970125