ASSEMBLY INSTRUCTIONS
3
OFF/O
Slide cord hook holster (D) onto right side, when facing thepower
washer unit (C) as shown.
Note: This step does not require any screws.
5
F
E
Connect the other end of high pressure hose (E) to spray gun
(F) by inserting the silver metal tip of high pressure hose into
the fitting just ahead of trigger guard. It will lock into spray gun
with a "click". Confirm hose is locked into spray gun by slightly
pulling on hose. The hose is now securely attached to spray
gun.
Note: DO NOT press button on underside of gun when con-
necting hose to gun.
8
D
ON/I
C
4
High Pressure Hose Assembly
The high-pressure hose (E) connects to the pump connector on
the front, bottom of the power washer unit (C). Pull back on the
high-pressure hose collar, then insert the O-ring fitting into the
pump outlet deep enough for the collar to be threaded. DO NOT
CROSS THREAD. If needed, position the power washer so you
can observe that the threads are started correctly. Twist the
collar clockwise until tight; at least six turns. WARNING: Failure
to properly tighten the high-pressure hose will result in the hose
slipping and popping off upon turning the unit on.
Note: DO NOT use pliers or locking pliers to tighten.
6
F
E
To release the high-pressure hose (E) from the spray gun (F),
press button (1) on the underside of the gun toward the trigger
guard. The hose (2) will slide out from the connection.
C
E
2