Electrical Specifications /
1. All wiring must comply with local and national
electrical codes and must be installed by a
qualified electrician. If you have any questions
regarding the following instructions, contact a
qualified electrician.
2, Check available power supply and resolve any
wiring problems BEFORE installing and operating
this unit.
3. For your safety and protection. This unit is
grounded through the power cord when plugged
into a matching wall outlet.
If you are not sure
whether your wall outlet is properly grounded,
please consult a qualified electrician.
Electric Shock Hazard
If the air conditioner has a serial plate rating
up to and including 7.5 amps, the unit maybe
on a fuse or circuit breaker with other devices
However, the maximum amps of all devices
on that fuse or circuit breaker can not exceed
the amps of the fuse of circuit breaker.
If the air conditioner has a serial plate rating
greater than 7.5 amps, it must have its own
fuse or circuit breaker, and no other device or
unit should be operated on the fuse or circuit
breaker.
To avoid the possibility of personal injury,
disconnect power to the unit before installing
or servicing.
4. The wall outlet must match the plug on the
service cord supplied with the unit DO NOT use
plug adapters or extension cord.
5. The rating plate on the unit contains electrical
and other technical data. The rating plate is
located on the right side of the unit.
RECEPTACLE AND FUSE TYPES
1
COOLING CAPACITY
5K
RATED VOLTS
125
AMPS
15
WALL OUTLET
I
1
V
i
J
FUSE SIZE
15
Time Delay Fuse
(or circuit breaker)
Plug type
Table 1
©