Technical Data - Grohe Tectron 37 321 Manual De Montaje

Ocultar thumbs Ver también para Tectron 37 321:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 11
GB
Safety notes
• Installation is only possible in frost-free rooms.
• The control electronics are only suitable for indoor use.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification.

Technical data

• Electrical supply
(transformer 230 V AC/12 V AC)
• Power consumption
(Standby power consumption < 1 VA)
• Detection zone with Kodak Gray Card, grey
side, 8x10", landscape (factory setting):
• Flow volume
• Intermediate flush
• Automatic flush
24 hours (factory setting: activated)
• Type of protection
• Minimum flow pressure
• Operating pressure
• Recommended flow pressure
• Test pressure
• Temperature
• Pipe
• Connection thread
• Integrated isolating valve
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature for ball impact test
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and
rated current.
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Special accessories
• Infrared remote control (Prod. no. 36 206) for changing the
factory settings and selecting special functions.
Operation
The infrared electronics emit invisible, pulsed light. If this light
is reflected by a user for a minimum of 10 s (= minimum delay
time) and is then received again by the electronic system, the
solenoid valve is activated approx. 1 second after the user
moves away. The solenoid valve opens and the bowl is
flushed.
The range of sensitivity is dependent upon the reflective
properties of the object.
Installation
Plaster and tile the wall, excluding the area of the structural
shell protection.
Final installation
1. Cut off structural shell protection (A) flush with the wall,
see Fig. [1].
2. Open isolating valve (B) and flush pipe for at least 5 s,
then close isolating valve (B) again, see Fig. [2].
230 V AC
1.8 VA
3. Fit upper part (C) of the transformer to base (D),
see Fig. [3a] or [3b], remove protection from contact
pins first.
45cm
4. Remove flushing aid (E) and screw in solenoid valve (F) by
2 l (factory setting)
hand, see Fig. [4].
Every 2 min (max. 14x)
5. Align frame (G) and fasten using screws (H), see Fig. [5].
(factory setting: activated)
6. Connect upper part (C) of the transformers and solenoid
valve (F) with electronics (J), see Fig. [6].
IP 55
7. Open isolating valve (B), see Fig. [2].
0.5 bar
8. Engage plate (K) at bottom of frame (G) and snap into
max. 10 bar
position at bottom by gently pushing upwards, see Fig. [7].
1 – 5 bar
9. Fasten plate (K) using locking screw (K1).
16 bar
max. 45 °C
Make settings
DN 15
G ½
Setting mode
The flow volume can be checked and changed in setting mode
(see Setting the flow volume).
A
The detection zone of the fitting can be checked. The indicator
2
lamp in the sensor system of the fitting illuminates in setting
2500 V
mode when the detection zone of the fitting is reached by an
100 °C
approaching user.
Flushing is immediately triggered when the detection zone is
exited again. The minimum delay time of 10 s is not available
in setting mode.
To activate setting mode, proceed as follows:
1. Remove locking screw (K1), see Fig. [8].
2. Remove plate (K) upwards from frame (G).
3. Disconnect the power supply to the electronics and
reconnect after 5 s, see Fig. [9].
Setting mode is automatically terminated after 3 min.
Setting the flow volume
The factory-set flow volume is approx. 2 litres at a flow
pressure of 3 bar.
The flow volume can be changed as follows:
1. Activate setting mode (see above).
2. Hold hand at a distance of 5 – 10cm in front of the fitting
sensor system.
The indicator lamp in the sensor system of the fitting flashes
quickly.
3. After approx. 5 s, the indicator lamp extinguishes
automatically.
4. Remove hand from the detection zone (at least 60cm).
5. Again hold hand at a distance of approx. 5 – 10cm in front of
the sensor system.
The flow volumes are indicated via the indicator lamp in the
sensor system by groups of flashing signals separated by a
pause.
Switch off voltage supply!
4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Tectron 37 336

Tabla de contenido