Functions and Operation
1. Functions:
Press and hold on "POWER" button for 5 seconds to activate the control panel.
1.1 Temperature setting:
"FRIDGE/FREEZER", "+", and "–": the buttons to set temperature of fridge and freezer compartments.
Press "FRIDGE/FREEZER" to enter the temperature setting mode and switch between the fridge temperature and the
freezer temperature.
Press "+" or "–" to set the temperature.
Fridge temperature "+"setting cycle: 1°C
Fridge temperature "–" setting cycle: 7°C
Freezer temperature "+" setting cycle: -12°C
Freezer temperature "–" setting cycle: -18°C
Press "FRIDGE/FREEZER" for 3 seconds to switch between "C" and "F".
If there is no operation for 5 seconds, it will automatically exit the setting mode and enter the display voltage mode.
1.2 Power off:
Hold on "POWER" button for 5 seconds to turn off the refrigerator for any extended period of non-use.
2. Battery Monitor:
When the communication is normal, the digital tube displays the voltage, and the power-on displays "--".
"Normal": Normal voltage range: 10.4~14.5V
"OV ALM": Over voltage alarm: >=14.5V
"UV ALM": Under voltage alarm: <=10.4V
When the voltage is too high, "OV ALM" icon will turn on.
When the voltage is insufficient, "UV ALM" icon will turn on. Meanwhile, there will be a beeping sound for 3
seconds to remind the user.
3. Deactivating the defrosting function:
In the voltage display mode, press and hold "+" for 5 seconds to deactivate the defrosting function, and the control screen will
alternately display voltage / "HC".
After 48 hours, the normal defrosting function will be restored.
4. Error Codes:
E2
Fridge sensor failure
E3
Freezer sensor failure
E4
Frosting sensor failure
H1
Over voltage alarm
LO
Low voltage alarm
ED
Door alarm
EC
Communication failure
CCD-0007851 Rev: 08-15-23
7°C (34°F
45°F)
à
à
1°C (45°F
34°F)
à
à
-18°C (10°F
0°F)
à
à
-12°C (0°F
10°F)
à
à
- 7 -