Descargar Imprimir esta página

Teka CNL 6810 Manual Del Usuario página 22

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 14
• If the electrical connection is done through a plug and this
remains accessible after installation, then it is not necessary to
provide the mentioned separation device.
• The air must not be discharged into a flue that is used for
exhausting fumes from appliances burning gas or other fuels
(not applicable to appliances that only discharge the air back
into the room).
• The lower part of the extractor must be located at a minimum
height of 50 cm above the hob for electric cookers and 65 cm
for gas cookers. If the instructions of a gas cooker indicate a
greater distance these must be observed.
• Before installing the extractor consult the local rules and
regulations in force with respect to the discharge of air and
fumes.
• When the extractor is working at the same time as other non-
electrical cooking equipment, the outlet air pressure must not
exceed 4 Pa (4x10
• Before connecting the extractor to the mains, check that both
the voltage and the frequency conform to that shown on the
characteristics label located inside the extractor.
• To achieve optimum performance the length of the outlet hose
should not exceed 4 meters or include more than two 90º
angles (elbows).
• Although venting to the outside is recommended, activated
carbon filter may be used to allow the gas to be returned to the
kitchen through the outlet pipe.
Cleaning
• Before carrying out any cleaning or maintenance activities,
ensure that the extractor is disconnected from the mains.
• There is a fire risk if cleaning is not carried out in accordance
with the instructions.
• Do not allow grease to accumulate in any part of the extractor,
especially in the grease filters as this COULD PRODUCE A FIRE
RISK!
• The grease filters and the internal part of the extractor must be
cleaned at least once a month depending on how often the
22
-5
bar).

Publicidad

loading