Remove the battery pack.
Place the open end of the soap injection hose over the
barbed fitting on the pump.
Place the filter end of the soap injection hose in the bot-
tom of the detergent bottle/container.
NOTE: The machine setting of this unit is 20:1, which usu-
ally allows the use of 1 gallon pressure washer detergent
without further dilution. Check your detergent instructions
to be sure additional dilution is not necessary.
Install the blue or black soap nozzle on the spray wand.
Reinstall the battery pack and turn the pressure washer
on.
Squeeze the trigger and wait approximately 5 seconds
for the detergent to appear.
Spray the detergent on a dry surface using long, even,
overlapping strokes. To prevent streaking, do not allow
detergent to dry on the surface.
Before shutting off the motor:
Place the soap injection hose with filter in a bucket of
clean water.
Spray the clear water through the spray wand until the
tank is empty.
If any soap remains in the spray, repeat with a second
tank of clean water.
Shut off the motor.
NOTE: Shutting off the motor will not relieve pressure in the
system. Pull trigger to release water pressure.
RINSING WITH THE PRESSURE WASHER
Turn off the pressure washer and shut off the water sup-
ply. Pull trigger to release water pressure.
Engage the lock out on the trigger handle by pushing up
on the lock out until it clicks into the slot.
Remove the soap nozzle by placing hand over nozzle then
pulling back the quick-connect collar. Place soap nozzle
in the nozzle storage area on the machine.
Select the right nozzle for the job. See the chart shown
earlier in the manual to select the appropriate nozzle.
OPERATION
Start at the top of the area to be rinsed and work down,
overlapping the strokes.
USING PUMP PROTECTOR
See Figure 15.
Regular use of a commercially available pump protector
prolongs the life of the pressure washer by removing hard
water mineral deposits, lubricating pump seals and pistons,
and preventing freeze damage. Pump protector should be
added to the unit after every use and before storage. Pump
protector can be purchased at the retailer where you pur-
chased your pressure washer, or by calling customer service.
The instructions that follow are typical for adding pump pro-
tector but you should always verify the specific instructions
provided by the manufacturer of the pump protector used.
Turn off the pressure washer motor, remove the battery
pack, and shut off the water supply. Pull trigger to re-
lease water pressure.
Disconnect all hoses.
Unscrew threaded top from pump protector bottle and
remove paper seal from bottle. Reinstall top on bottle
and tighten securely.
NOTE: The rubber seal should remain inside the threaded
top. If it comes out, be sure to replace before reinstalling
the top.
Remove bottle cap and attach threaded end of bottle
securely to pressure washer pump water intake.
Squeeze bottle to inject contents into pump.
Pump is protected when the protector fluid exits the
pump outlet.
MOVING THE PRESSURE WASHER
Turn the pressure washer off. Point nozzle in a safe direc-
tion and pull trigger to release water pressure.
Remove the battery pack.
Using the carrying handle, get a firm grasp of the unit.
Lift the unit into a safe and comfortable carrying position.
Move machine to the desired location.
DO NOT attempt to move the unit by pulling on any of
the hoses.
12 — English