6b1. Calibration menu
The Calibration menu consists of two (2) sub-menus:
• pH Calibration menu: used to run the calibration routine, start the wizard
messages, at pH measure is available calibration method: two buffer
solution 7 and 4pH, single one buffer solution 7pH only, and reference
value it is possible to set a pH value present in the water pool. The
controller device gives a quality probe to check the expected lifetime.
• ORP Calibration menu: used to run the calibration routine, start the wizard
messages, at Redox measure is available calibration method: sigle buffer
solution 465mV and reference value it is possible to set a Redox value
present in the water pool. The controller device gives a quality probe to
check the expected lifetime.
Note: please check sections 6e and 6f for step by step calibration routine.
6b2. Setup menu
The Setup menu consists of two (2) sub-menus:
• pH
• ORP
Scroll through the menu using
Setup pH
The Setup pH menu consists of six (4) sub-menus:
• Setpoint: 7.4pH (range 6-8pH) Set the pH value keep in the pool.
• Setpoint Type: Acid (Acid/Alka) The dosing type to regulate the pH value.
Acid: add chemical Acid product to reduce pH value
Alka: add chemical Alkaline product to increase pH value.
• Manual Temperature: 25°C, automatic temperature pH compensation
• OFA Time: OFF Over Feed alarm time in minutes (OFF...60'), it is a
maximum relay time activation.
• *Time ON: 180 seconds (range from 5 to 360 seconds)
• *Time OFF: 360 seconds (range from 5 to 360 seconds)
*Note:
The items Time On and Time OFF will be displayed if the Timed dosing method
is set in the Advanced menu.
Time OFF must be equal to or greater than Time ON.
Scroll through the menu using
, select the item and confirm with
g
g
, select the item and confirm with
ProChem Single | pH · ORP
Only use spare parts supplied by Hayward brands ®
Main Menu
CALIBRATION
CALIBRATION
PH
CALIBRATION
ORP
Main Menu
SETUP
SETUP
PH
.
SETUP
ORP
SETUP
PH
SETPOINT
SETPOINT TYPE
MAN.TEMPERATURE
OFA TIME
.
TIME ON
180 SEC
TIME OFF
360 SEC
Page 10 on 25
7.4pH
ACID
25°C
OFF