Setup ORP
The Setup ORP menu consists of three (3) sub-menus:
• Setpoint ORP: 700mV (range 250-900mV) Set the ORP value to keep in
the pool.
• Setpoint Type: Low (LOW/HIGH) Type of dosing regulation.
Low: the pump doses chlorine product to increase chlorine value,
High: the pump doses bisulfite product to reduce chlorine value.
• OFA Time: OFF Over feed alarm timer, maximum activation time (range
OFF...1m to 240min).
• *Time ON: 180 seconds (range from 5 to 180 seconds)
• *Time OFF: 360 seconds (range from 5 to 360 seconds)
*Note:
The items Time On and Time OFF will be displayed if the Timed dosing method
is set in the Advanced menu.
Time OFF must be equal to or greater than Time ON.
Scroll through the menu using
6b3. Advanced menu
The Advanced menu consists of eleven (11) sub-menus:
• Language
• Pump Configuration
• Password
• Flow
• Control Panel
• Wifi Setup
• Counters
• Calibration
• Dosing Type
• Power On Delay
• Flow Delay
Scroll through the menu using
g
g
, select the item and confirm with
, select the item and confirm with
ProChem Single | pH · ORP
Only use spare parts supplied by Hayward brands ®
SETUP
ORP
SETPOINT
SETPOINT TYPE
OFA TIME
TIME ON
.
180 SEC
TIME OFF
360 SEC
Main Menu
ADVANCED
ADVANCED MENU
LANGUAGE
ADVANCED MENU
PUMP CONFIG
ADVANCED MENU
PASSWORD
.
ADVANCED MENU
FLOW
ADVANCED MENU
CONTROL PANEL
ADVANCED MENU
WIFI SETUP
ADVANCED MENU
COUNTERS
Page 11 on 25
700mV
LOW
OFF