Descargar Imprimir esta página

Hayward ProChem pH Manual Del Propietário página 14

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 47
EN
Control Panel menu:
• Input measure: pH or ORP, in mV signal
• Input temperature measure: raw signal in °C
• Input Level Probe: on/off
• Input Flow: on/off , Trigger high voltage from circulation pump
• Relay1: off , press ok to close and simulate manual activation.
• Relay2: off , press ok to close and simulate manual action
Wi-Fi menu
WiFi parameters to connect by laptop in the WiFi network:
• SSID: KommSpot-5EFA5C
• Password:12345678
• IP address: 192.168.1.3
Counters menu: List of internal counters
• Pumps & Signals
• Buttons
• Alarms
• Calibration
• Reset
Calibration menu: setting the calibration method
• for pH: two point (7 and 4 pH), single point (7 pH), external reference pH value
• for Redox (ORP): single point (465mV), external reference redox value.
Dosing Type menu:
• Proportional
• Timed
• On/Off
• Off
Power on Delay menu:
Set timer (range 0..90 minutes); timer= 0 minutes, the function is disabled.
Flow menu:
Set timer (range 0..60 minutes); timer= 0 minutes, the function is disabled.
6c. Pump Priming
Keep pressed
for 3 seconds to prime the pump.
6d. View Parameters
Alarms list:
• Circ. Pump OFF
• LEV
• WDG
• OFA1 & OFA2
• Stand By
• Flow
• NO WiFi
LEV
LEV
ProChem Single | pH · ORP
Only use spare parts supplied by Hayward brands ®
7.4pH
28°C
750mV
28°C
Page 13 on 25
CONTROL PANEL
WI-FI SETUP
pH measure
Temperature
ORP measure
Temperature

Publicidad

loading

Este manual también es adecuado para: