Fault
Display shows "Please
clean brewing unit, re-
place and close
door.".
Display shows
"Voltage (V) incor-
rect.".
Display shows "Please
restart appliance.".
Display very frequently
shows "calc'nClean".
Coffee or milk froth
quality varies widely.
Milk froth quality var-
ies widely.
Coffee is not dis-
pensed or has slowed
to a trickle.
Set quantity is not
reached.
Cause and troubleshooting
Use no more than 2 level measuring spoons of
ground coffee.
There are problems with the power supply.
Only operate the appliance at 220 - 240 V.
Brewing unit is heavily soiled or cannot be removed.
Restart the appliance.
Clean the brewing unit.
Appliance has a fault.
Pull out the mains plug and wait 60 seconds.
1.
Re-insert the mains plug.
2.
Decalcified water still contains small amounts of lime.
Insert a new water filter.
1.
→ "Inserting and activating the water filter", Page 52
Set the corresponding water hardness.
2.
Incorrect or too little descaling agent used.
When descaling, only use suitable tablets.
Service programme has not been carried out in its en-
tirety.
Reset the service programme.
→ "Resetting service programmes", Page 66
Build-up of limescale in the appliance.
Descale the appliance.
Milk froth quality depends on the type of milk or plant-
based alternative used.
Optimise the result through the selection of the milk
or vegetable-based drink type.
Grinding level is set too fine.
Set a coarser grinding level.
→ "Adjusting the grinding level", Page 57
Heavy build-up of limescale in the appliance.
Descale the appliance.
Air is in the water filter.
Immerse the water filter in water with the opening
1.
facing upwards until no more air bubbles escape.
Reinsert the filter.
2.
→ "Inserting and activating the water filter", Page 52
Appliance is soiled.
Troubleshooting en
71