1.5
Components
01
Compressor unit
02
Intake filter
03
Oil filler plug
04
Mini ball valve (oil drain)
05
Oil inspection glass
06
Pressure pipe
07
Check valve
08
Vessel
09
Dirt arrester
10
Pressure switch with ON/OFF switch
11
Safety valve
12
Pressure gauge (vessel pressure)
13
Pressure gauge (working pressure)
14
Electric motor
15
V-belt pulley
16
V-belt
17
Fan wheel
18
Pressure reducer
19
Quick-action coupling (clean, regu-
lated compressed air)
20
Mist oiler
21
Quick-action coupling (oil-mist com-
pressed air)
22
Connecting hose
23
Console (compressor unit)
24
Console (electric motor)
25
Vibration damper
26
3/2-way value for automatic conden-
sate drainage
27
Control line (3/2-way valve)
28
Condensate collection pipe
29
Condensate evaporator
30
Operating panel
31
Regulating screw (mist oiler)
32
Water separator with filter
33
Float valve
34
Operating hours counter
35
Service outlet
36
Alternating current plug (service out-
let)
37
Three-phase
motor)
current
plug
(electric
MAS 500-10-60 D-Silent
38
Guide roller with locking brake
39
Maintenance flap
40
Hose rewinder (optional)
41
Fan wheel
42
Air inlet
L For equipment that does not have a safety
valve on the tank, the safety valve is lo-
cated
by
the
Chapter for more information1.6.2.
1.6
Maintenance
1.6.1 Cleaning the intake filter
1. Unscrew the intake filter. (Fig. 5a)
2. Clean the filter insert using the blow gun,
exchange the filter insert if necessary.
3. Screw the intake filter back on.
1.6.2 Replacing the safety valve
For compressors that have a safety valve by
the pressure switch:
1. Unscrew the cover plate (Figure 17a).
2. Pull cover plate down and forward.
3. Remove cover plate.
1.7
Compressor inspections
This compressor is subject to a type approval
inspection. As a result, inspections by an au-
thorised expert prior to commissioning are
no longer necessary. The prototype identi-
fication code is located on the compressor
specification plate.
We recommend that a "qualified person"
perform a pressure test on the vessel after
10 years, depending on general levels of
wear and tear.
A "qualified person" should be well informed
about Ordinance on Industrial Safety and
Health (formerly authorised expert)
Contact any of our approved service part-
ners. Most of our service partners have em-
ployees with expert qualifications.
L The papers accompanying the vessel are
approval documents and must be kept
throughout the service life of the vessel.
These specifications only apply in Germa-
ny. Equivalent regulations apply in other
countries.
pressure
switch.