2. MEASUREINSTALLATION
Dimensions for the most common installation are illustrated at right.
The minimum hood distance
above cooktop must not be less
than
24".
A
maximum
of 30"
above
cooktop
is highly
recommended
for best capture of cooking
impurities.
Distances over 30" are at the installer and users discretion.
3. PREPARETHE INSTALLATION
Cabinet, soffit,
decorative
flue or -
non=duct kit flue
HH0093A
Ceiling
Minimum distance between
the hood and cooktop:
24"
Recommended maximum
distance between the hood
and cooktop: 30"
Standard
36"
j
high cooktop
MINIMUM AND MAXIMUM DISTANCE
OVER COOKTOP
When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.
NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer.
Remove the installation kit from inside the hood.
Make sure that the following items are included:
- Wood strip (attached to back of hood)
- Installation manual
- Accessories including:
• Baffle filters: 30" and 36" hoods come with 3 baffle filters; 42" and 48" hoods come with 4 baffle filters
• Baffle filters handles (taped inside the hood)
• 3W' x 10" adapter/damper
(included with internal single blower hood)
• 41/2"x 181/2"adapter (included with internal double blower hood)
• In-line and exterior blower rough-in plate model 332KR (mounted inside all external blower hoods)
• Bag of parts including:
4 flat head screws no. 10-2", 8 screws no. 8 x 3/4", 2 wire connectors, 3 wall anchors,
3 washers 13/64" ID x 3/4" OD, 1 wire clamp, 8 mechanical screws no. 8-32 x 1/4", 4 no. 8 x 3/8" screws
Parts sold separately:
- In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition)
- Exterior blower assembly 331 H, 332H, 335 or 336
- Shielded GU10 50W halogen bulbs (2 required for 30" and 36" hood widths, 3 required for 42" and 48" hood widths)
- RMP Series Backsplash (optional)
- ANKE60 Series Recirculation kit, mandatory for non-ducted installation (models with built-in blower(s) only)
- AEE Series Decorative flue, to be installed over the hood (optional)
- Transitions, duct, elbows, dampers, wall and roof caps.
Refer to pages 3 and 4 for a complete list of venting options and model numbers.
-6-