Error message/
Response of mag-
net button
Indication flashes
red for approx. 2
seconds
Indication lights up
red for approx. 2
seconds when the
motor is switched
off
Indicator lights up
red continuously
Indicator flashes
red continuously
Meaning
Overload of motor.
Motion sensor has actu-
ated.
Magnetic foot cannot be
switched off sooner than
2 seconds after the motor
has been switched off.
Incorrect mains voltage or
mains frequency.
A button or switch is
already pressed upon
plugging in the power
supply cord.
Power tool is defective.
Corrective action
After malfunction correction, the power
tool can be switched on again.
Pay attention that the set-up surface for
the magnetic foot is flat, clean, rust-free
and ice-free.
Remove varnish, putty/filler layers and
other materials.
Prevent an air gap between the magnetic
foot and the set-up surface. The air gap
reduces the magnetic holding power.
Do not use the machine on hot surfaces,
as this could result in a permanent reduc-
tion of the magnet holding power.
After malfunction correction, the power
tool can be switched on again.
Wait until the red LED goes out and the
green LED lights up or flashes.
Unplug the machine, correct the error
and plug in the power supply cord again.
If the error message is still present, send
the machine to your FEIN customer ser-
vice agent.
Send the machine to your FEIN customer
service agent.