Descargar Imprimir esta página

Buffalo 600 Serie Manual De Instrucciones página 5

Bano maria
Ocultar thumbs Ver también para 600 Serie:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32
Maintaining Water Levels
It is important to regularly check the water level in the tank.
Always keep the water level above the 'MIN' mark on the inside of the tank during operation.
Damage to the heating element can occur if the tank boils dry and the element may have to be
replaced. This is not covered by the BUFFALO warranty.
Thermal Cut-out Reset
The appliance is fitted with a Thermal Cut-Out safety switch. Should the temperature exceed safe levels
the appliance will automatically cut off power.
The thermal Cut-out switch is located on the front of the unit. To reset the appliance after a sufficient
cool-down period:
1. Unscrew the reset switch cover.
2. Press the small reset switch down until it clicks, using a blunt pointed instrument.
3. The appliance is now reset and can be used as normal.
Cleaning, Care & Maintenance
WARNING:
Always turn off and disconnect the appliance from the power supply before cleaning.
Always allow the appliance to cool before emptying or cleaning.
Wipe down the exterior of the appliance with a damp cloth.
Some cleaning agents may cause damage when used for a prolonged period on stainless steel. Use a
suitable stainless steel cleaner. Daily cleaning is recommended.
Wash all removable parts in warm, soapy water.
Dry the exterior thoroughly.
De-scaling
To maintain energy efficiency and prolong the life of the appliance, regular de-scaling is needed.
Pour a solution of neutral cleaner and water into the appliance.
Brush gently with a soft brush.
Discard the solution and flush out thoroughly with clean water to remove any solution residue.
Wipe dry the appliance, especially the bottom part of the water tank.
Note: Use a suitable cleaner and always follow the instructions on the cleaner container.
BUFFALO recommend that this appliance is de-scaled every 3 months or more often in hard
water areas.
IMPORTANT: Failure to de-scale or maintain will invalidate your guarantee.
CU480_ML_A5_v2_20231207.indb 5
EN
5
2023/12/7 18:30:18

Publicidad

loading

Este manual también es adecuado para:

Cu480Cu480-e