Troubleshooting
A qualified technician should carry out repairs if required.
Fault
The unit is not
The unit is not switched on
working
Plug or lead is damaged
Fuse in the plug has blown
Mains power supply fault
Appliance does
Faulty thermostat
not reach set
Faulty heating element
temperature, or
slow to heat up
Appliance heats up
Indicator light has expired
but indicator light
does not come on
On/off indicator
Faulty on/off switch
light comes on but
Faulty heating element
appliance does not
heat up
Thermostat set incorrectly
No power
Thermal cut-out activated
Appliance
Thermostat damaged
overheats
Technical Specifications
Note: Due to our continuing program of research and development, the specifications herein may be
subject to change without notice.
Model
Voltage
230V 1N~,
CU480
50-60Hz
6
CU480_ML_A5_v2_20231207.indb 6
Probable Cause
Temperature
Power
Range
1500W
30ºC - 90ºC
Solution
Check the unit is plugged in correctly and
switched on
Replace plug or lead
Replace the fuse
Check mains power supply
Consult a qualified technician
Consult a qualified technician
Consult a qualified technician
Consult a qualified technician
Consult a qualified technician
Check thermostat
Please check your machine is safe with no
obvious damage and then press the re-set
switch
Switch Off immediately. Consult a qualified
technician
Dimensions
Capacity
H x W x D mm
GN 1/1 150mm
280 x 400 x 600
Weight
11.5kg