en-us Electrical installation - GROUNDING INSTRUCTIONS
Electrical installation - GROUNDING INSTRUCTIONS
5 Electrical installation - GROUNDING INSTRUCTIONS
Read these instructions to safely connect your appliance to the electrical supply.
Electrical installation - GROUNDING INSTRUCTIONS
5.1 Electrical requirements
Make sure your electrical installation supports the following requirements.
WARNING
Electrical grounding instructions
This appliance is equipped with a three-prong grounding plug for your protection against shock hazard and should be
▶
plugged directly into a properly grounded receptacle. DO NOT cut or remove the grounding prong from this plug.
Model
MBCS
5.2 Electrical connection
WARNING
The voltage used must be the same as specified on this
appliance. Using a higher voltage is dangerous and may
result in a fire or appliance damage.
Electrical requirements:
All 120 volt models must be plugged into a mating 3-
¡
prong, grounding-type receptacle.
The receptacle must be connected to a properly
¡
dedicated grounded and polarized electrical power
supply rated at 120 VAC, single phase, 60 Hz.
15 A electrical supply with a fuse or a circuit breaker.
¡
This product must be connected to a dedicated supply
¡
circuit of the proper voltage and frequency.
Wire size must conform to the requirements of the
¡
National Electric Code or the prevailing local code for
this rating.
The power supply cord should be plugged into a
¡
separate 15 A single-phase grounded receptacle outlet.
The outlet box should be located in the area behind the
¡
appliance.
The outlet box and dedicated supply circuit should be
¡
installed by a qualified electrician and conform to the
National Electrical Code or the prevailing local code.
The voltage used must be the same as specified on the
¡
rating plate of this appliance.
→ "Rating plate location", Page 13 . Using a higher
voltage is dangerous and may result in a fire or
appliance damage.
Using a lower voltage will cause slow cooking. The
manufacturer is not responsible for any damages
resulting from the use of the appliance with any voltage
other than specified.
The appliance should only be connected to a dedicated
¡
circuit (with ground) that has been installed according to
relevant regulations.
10
Connection
NEMA 5-15
6 Installation procedure
Installation procedure
Installation procedure
6.1 Preparing the cabinet
Requirement: The cabinet needs to be level and square.
Attach the foam strips around the top edges of the base
1.
pan as shown.
Disconnect power supply to the outlet at the circuit
2.
breaker box.
Draw a centerline at the cabinet bottom.
3.
Circuit requirements
120 VAC / 60 Hz; 15 A