GB
MAINTENANCE
7.
MAINTENANCE
7.1
GENERAL WARNINGS
ELECTRIC HAZARD!
Maintenance and/or repair operations on any of the appliance components must be done only after disconnecting the power
supplies (Disconnecting the plug from the mains).
ATTENTION!
Only qualified personnel must be allowed to carry out maintenance operations or access powered parts of the machine.
ELECTRIC HAZARD!
Disconnect the electric current before carrying out cleaning or maintenance.
For repairs, if necessary, contact a Service Centre authorized by the manufacturer. Use and demand genuine spare parts.
7.2
PROGRAMMED MAINTENANCE
FREQUENCY
Before each start up
Weekly
Every 15,000
operating cycles (about 100
hours of service)
Every 25,000
operating cycles (about 200
hours of service)
Every two oil changes
Every 1000
hours of service
Every 6 months
7.3
CARE AND CLEANING OF THE VACUUM PACKAGING MACHINE
ELECTRIC HAZARD!
Danger of electric shock ! Remove the machine plug from the power socket. Do not
GB
use water or steam jets.
DANGER! Danger of burns: if alcohol-based or inflammable disinfectant products are
used, ventilate the area. Do not use naked flames near the machine! Do not smoke!
ATTENTION! Danger of injury! Use personal protective equipment. Do not use
caustic products, acids or aggressive products such as muriatic acid. Read the
instructions on the detergent product or disinfectant pack carefully.
WARNINGS! Use alcohol-based disinfectants.
The machine must be cleaned and disinfected every time after use.
Operation and maintenance manual / Ed. 10 - 2005
MACHINE PART
Pump
Power cable
Plexiglas cover
Red silicone
and Plexiglas cover gasket
Machine and vacuum chamber
Sealing bar connection wire
Sealing bar
Pump
Appliance with 4 - 8 - 12 m
/h pumps
3
Appliance with 18 - 25 - 40 - 60 - 100 m
Pump
40 - 60 - 100 mc/h pumps
Pump
Check the oil colour and level; top up the level,
or change it completely if the colour is dark or
whitish.
Check to make sure it is intact, replace if
damaged (Contact a specialist Service Centre).
Check to make sure it is intact; if cracks or
streaks are present, contact Customer service
for replacement.
Check to make sure they are inserted properly
in their seats; replace if damaged.
Clean to remove impurities, oil and grease.
Check to make sure it is connected.
Clean the upper part with a damp cloth.
Run the pump for about 30 minutes (using the
Pump or Jars function) to allow removal of
water from the pump oil.
Change the pump oil
(call a specialist Service Centre).
/h pumps
Change the pump oil
3
(call a specialist Service Centre).
Change the pump exhaust filter (A)
(call a specialist Service Centre).
Change the oil filter
(call a specialist Service Centre).
Change the pump oil.
(call a specialist Service Centre).
62
VACUUM CHAMBER
PACKAGING MACHINES
ACTION
A
REV. 00 - Cod.: 1500154