Trouble shooting
Problem
In 230 Vw operation: the
refrigerator does not
work.
The refrigerator does not
cool sufficiently.
24
Possible cause
The fuse of the
230 Vw connection is
defective.
The thermostat knob is
in position "0".
The air circulation
around the ventilator is
insufficient.
The evaporator is iced. Defrost the refrigerator.
The temperature is set
too high.
The gas pressure is
incorrect.
The ambient tempera-
ture is too high.
Too many foods at the
same time were put
into the refrigerator.
The door is not closed
properly.
More than one source
of energy is used.
RM122, RM123
Remedy
Replace the fuse.
Turn the thermostat knob to
position "1", "2" or "3".
Remove any parts such as
covers.
Set a lower temperature.
Set the correct gas pressure.
Provide a lower ambient
temperature.
Remove some of the food.
Close the door.
Use only a power source.