OBJ_BUCH-1735-003.book Page 17 Thursday, March 14, 2013 9:40 AM
7 Laser warning label
8 Magnets
9 Battery lid
10 Laser outlet opening for point operation
11 Laser viewing glasses*
12 Tripod*
13 Wall holder
14 Metal surface for line operation
15 Metal surface for point operation
16 Adjusting screw of wall holder
17 1/4" tripod mount of wall holder
* The accessories illustrated or described are not included as standard delivery.
Technical Data
Point and line laser
Article number
Working range to approx.
– Line Operation*
– Point Operation
Levelling Accuracy**
Operating temperature
Storage temperature
Relative air humidity, max.
Laser class
Laser type
Batteries
Operating life time, approx.
Weight according to EPTA-Procedure 01/2003
Dimensions (length x width x height)
* when using the wall holder 13; under unfavourable conditions such as intense sun irradiation, the
working range is smaller
** when the measuring tool is positioned correctly (see "Positioning the Measuring Tool", page 19)
Bosch Power Tools
English | 17
PLL 1 P
3 603 F63 300
5 m
20 m
±0.5 mm/m
+5 °C...+40 °C
–20 °C...+70 °C
90 %
2
635 –650 nm, <1 mW
2 x 1.5 V LR03 (AAA)
15 h
0.1 kg
154 x 24 x 30 mm
1 619 929 L48 | (14.3.13)