Descargar Imprimir esta página

Amana ABL192ZFES Guía De Uso Y Cuidado página 19

Publicidad

Idiomas disponibles

Idiomas disponibles

Water F ilter
(select m odels)
System
Specification
and Performance
Data Sheet
Refrigerator
Water
Filter Cartridge
Model
UKF8001AXX
Specifications
Service Flow Rate (Maximum) .............................................
0.78 GPM (2.9 L/min)
Rated Service Life UKF8001AXX-750
(Maximum) ......750 gallons/2838
liters
Maximum
Operating
Temperature ..................................... 100° F/38 ° C
Minimum
Pressure Requirement ........................................ 35 psi/241
kPA
Minimum
Operating
Temperature ...................................... 33 ° F/1 ° C
Maximum
Operating
Pressure ............................................. 120 psi/827
kPA
a 3M Compa¢_ p
1000 Apollo Road
Eagan, Minnesota
55121-2240
651.450.4913
EPA EST #35917-MN-1
Performance
Data
Parameter
Chlorine
T&O
Particulate**
100834/B
USEPA
MCL
Standard No. 42: Aesthetic Effects
Influent
Challenge
Concentration
2.0 mg/L _+10%
Min. Required
Reduction
50%
Influent
Average
1.88 mg/L
5,700,000
#/ml
Effluent
Average
Maximum
_0.05136364 mg/L
0.06
mg/L
30,583
#/nil
69,000
#/ml
% Reduction
Average
Minimum
>9726%
96.84%
99.52%
98.94%
at least
10,000
particles/ml
85%
Parameter
Turbidi b,
Cysts
Asbestos
Lead at pH 6.5
Lead at pH 8.5
Mercury
at pH 6.5
Mercury
at pH 8.5
Atrazine
Benzene
Carbofuran
1,4-Dichlolobenzene
Lindane
Toxapbene
USEPA
MCL
1 NTU**
99.5%
Reduction
99% Reduction
0.015
mg/L
0.015
mg/L
0.002
mg/L
0.002
mg/L
0.003
m_iL
0.005
m_iL
0.04
m g/L
0.075 m g/L
0.0002
m g/L
0.003
mg/L
Standard
No. 53: Health
Effects
Influent
Challenge
Concentration
11 ± 1 NTU***
Minimum
59,OOO/L
107108 fibers/L;
fibers >10 nlicron/eters
in length
0.15 mg/L
+ 10%
0.15 mg/L
+ 10%
.006 mg/L
_+ 10%
.006 mg/L
_+ 10%
0.009
m0/L
+ 10%
0.015
m(iL
_+ 10%
0.08 m g/L
_+ 10%
.225 m g/L
_+ 10o/o
0.002
m g/L + 10%
0.015
± 10%
Influent
Average
10.7 NTU
166,500
#/L
155 MF/L
0.153 mg/L
0.150
mg/L
0.006
mg/L
0.006
mg/L
O.OO9 m_)/L
O.014 nl_iL
0.081
m g/L
0.208
m g/L
0.002 m g/L
0.015
mg/L
Effluent
Average
Maximum
0.31 NTU
.049 NTU
<1 #/L
<1 #/L
<1 MF/L
<1 MF/L
<.001 mg/L
<.001 mg/L
<.001 mg/L
<.001 mg/L
0.0003 mg/L
0.0005 mg/L
0.0008 mg/L
0.0015 mg/L
<0.002 mg/L
0.002 mg/L
0.0006 mq/L
0.0011 nyiL
<0.001 mg/L
<0.001 mg/L
<0.0005 m g/L
<0.0005 m g/L
0.00O mg/L
<0.0001 mg/L
<0.001 mg/L
<0.001 mg/L
% Reduction
Average
Minimum
97.09%
95.20%
>99.99%
>99.99%
>99.99%
>99.99%
>99.35%
>9929%
>99.33%
>9929%
95.70%
90.91%
86.22%
75.93%
76,99%
75.31%
95.71%
92.14%
98.74o/o
98.46o/o
99.76o/o
99.74o/o
98.72%
96.50o/o
92.97%
91.67%
Min. Required
Reduction
0.5 NTU
>99.95%
99%
0.10 mg/L
0.10 mg/L
0.002 mg/L
0.002 mg/L
0.003 mg/L
0.005 mq/L
0.04 mq/L
0.075 mg/L
0.0002 mg/L
0.003 mg/L
* Tested
using
a flow
rate of 0.78 gpm;
pressure
of 60 psig;
pH of 7.5 + 0.5; temp.
of
68 ° + 5° F [20 ° + 3 ° C]
** Measurement
in Particles/nil.
Particles used were 0.5 - 1 microns
*** NTU - Nephelometric
Turbidity Units
General Use Conditions
Read this Performance
Data Sheet and compare the
capabilities
of this unit with your actual water
treatment
needs.
DO NOT use this product where water is
microbiologically
unsafe or of unknown
quality
without adequate
disinfection
before or after the
system. System certified
for cyst reduction
may be
used on disinfected
water that may contain
filterable
cysts.
USE ONLY WITH COLD WATER SUPPLY. CHECK
FOR COMPLIANCE
WITH THE STATE AND LOCAL
LAWS AND REGULATIONS.
Standard
No. 42: Aesthetic
Effects
Taste and Odor
Reduction
Clllorine
Taste & Odor
Mechanical
Filtration
Unit
Particulate
Reduction
Class
1
Tested and certified
by NSF IntemaUonal
against
ANSI/NSF
Standards
42 & 53
in models
UKF8001AXX-750
for the reduction
of:
Standard
No. 53: Health
Effects
Cbenlical
Reduction
Unit
Lead, Atrazine,
Lindane,
Benzene,
Carbofuran,
1,4- DicllloT obenzene,
Mercury
& Toxapllene
Reduction
Mechanical
Filtration
Unit
Cyst, Turbidity
and Asbestos
Reduction
The PuriClean :_II retractable
water filtration
system
uses a UKF8001AXX
replacement
cartridge.
Timely
replacement
of filter cartridge
is essential for
performance
satisfaction
from this filtration
system.
Please refer to the applicable
section of your Use &
Care Guide for general operation,
maintenance
requirements
and troubleshooting.
This system has been tested according to ANSI/NSF
42
and 53 for reduction of the substance listed above. The
concentration
of the indicated substances
in water
entering the system was reduced to a concentration
less
than or equal to the permissible limit for water leaving
the system, as specified in ANSI/NSF
42 and 53.
18

Publicidad

loading

Este manual también es adecuado para:

Abb2221fezAbb1922fes0Abl2037fes0Abl1922fes0