6.1.1 Reference guidelines
Safety:
Insulation:
Pollution degree:
Max height of use:
Measurement category:
6.1.2 General data
Mechanical specifications
Dimensions (L x W x H):
Weight (including batteries):
Max conductor size:
Power supply
Battery type:
Low battery indication:
Battery life:
Auto Power OFF
Display
Characteristics:
Sample rate:
Conversion mode:
6.2 ENVIRONMENTAL CONDITIONS
6.2.1 Climatic conditions
Reference temperature:
Operating temperature:
Storage temperature:
Storage humidity:
Temperature coefficient:
6.3 ACCESSORIES
6.3.1 Standard accessories
• Test leads
• Carrying bag
• Batteries
• User manual
This instrument satisfies the requirements of Low Voltage Directive 2006/95/EC
IEC/EN61010-1, IEC/EN61010-2-032/-2-033
double insulation
2
2000m (6562ft)
CAT IV 600V, CAT III 1000V to ground
193 x 54 x 31mm (8 x 2 x 1in)
280g (10 ounces)
16mm (1in)
2x1.5V alkaline batteries type AAA LR03
" " is displayed
approx 300 hours
after 20min of idleness (disabled)
4 LCD, 9999 counts plus sign, decimal point
and backlight
2 times/sec
TRMS
23 ± 5°C (73 ± 41°F)
0 ÷ 30°C (32 ÷ 86°F) (80%RH)
30 ÷ 40°C (86 ÷ 104°F (75%RH)
40 ÷ 50°C (104 ÷ 122°F (45%RH)
-20 ÷ 60°C (-4 ÷ 140°F)
<80%RH
0.2 x specified accuracy /°C, <18°C, >28°C
(LVD) and of EMC Directive 2004/108/EC
EN - 15
HT100

Publicidad