Descargar Imprimir esta página

Bayrol smart&easy CONTROL MODULE Instrucciones De Uso página 24

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Electric connection of additional functions
5
The following installation instructions provide an overview of the various connection options. Here, various examples
are used to illustrate how the Smart&Easy Control Module is connected to the various electronic components.
Important:
It must be ensured that all safety regulations are complied with during the electrical installation and that all component-
specific connection specifications are observed! To do this, carefully read the operating instructions of the devices to
be connected and compare them with the technical data of the Smart&Easy Control Module.
5.1 Single Speed Filter Pump (ON/OFF)
The connection of a filter pump with a fixed speed can be carried out according to the following wiring diagram.
The use of an appropriate contactor and motor circuit breaker is compulsory.
230 V AC + RCD (≤ 30 mA)
1
2
3
24
4
A1
A2
1
L1
3
L2
5
L3
By using a contactor, the hardware of the Smart&Easy Control
Module is protected by separating the control and main circuits.
2
T1
4
T2
6
T3
1
2
3
4
Hint
Motor Circuit Breaker
Contactor
Filter Pump
Connection to OUT 1 – 4 possible

Publicidad