Descargar Imprimir esta página

STAR Water Systems SJR05S Guía De Referencia Rápida

Pozo de poca profundidad bomba de chorro

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

SHALLOW WELL JET PUMP
MODEL #SJR05S
QUICK REFERENCE GUIDE.
SEE INSTRUCTION MANUAL FOR
COMPLETE DETAILS.
115 V
230 V
WARNING: You must match the voltage of
your pump to the existing power supply.
ELECTRICAL SHOCK ALERT
All electrical wiring or service should be done by
a qualified electrician.
5
4
CHECK TANK PRESSURE
1. Completely drain all water
from tank by turning off pump
and opening a faucet until
water stops.
2. Use a pressure gauge to
ensure it's set to 18 psi.
a. Use a tire pump to adjust
the psi to 18 psi.
b. If water leaks from the air
release valve, replace the
pressure tank.
a. Remove pressure gauge or discharge
tee plug (not included) from the top of the
discharge tee (not included). Remove the
Pressure
vent plug in front of the discharge tee.
gauge
Air release valve
Set to
18 psi
For use with a pressure tank. Do not use for irrigation applications.
1
1
CAUTION: Make certain that the power
source matches the pump requirements.
Pump has a dual voltage motor and can run on
either 115 V or 230 V.
Pump is pre-set at the factory to run
on 115 V.
1. To change voltage:
a. Power must NOT be connected.
b. Pull selector plug out approximately 1/4-in.
c. Rotate plug to align arrow to 115 V or 230 V
as desired.
d. Push plug back in approximately 1/4-in.
Voltage
selector
Ungrounded
line
Ground
CAUTION: All pumps must be primed by filling the cavity with water before they are first operated. This will take several gallons of
water, as the suction line must be filled in addition to the cavity of pump. Depending on the length of suction pipe, many gallons may be
needed to fill the entire system.
Pressure Gauge or
Discharge tee plug
Vent plug
b. Slowly fill the discharge tee with water
Questions, problems, missing parts? Before returning to your retailer,
call our customer service department at 1-800-742-5044,
7:30 a.m. - 5:00 p.m., EST, Monday - Friday.
2
Remove plastic plugs from
inlet and outlet openings.
1 in.
Discharge Pipe
To Tank
25 ft.
1-1/4 in.
max.
Suction Pipe
Voltage
selector
Well
Foot Valve
IL1957B
Vent Plug
Opening
until water overflows the vent plug
opening. NOTE: Before turning on
pump, loosely replace vent plug and open
several outlets or faucets to allow water
flow during priming.
3
Connect pump to tank (not included) as
shown. Most pressure tanks will have a 1 inch
inlet elbow on the bottom. Using 1 in. fittings (not
included), connect this elbow to pump as shown.
A union (not included) is recommended for easy
connection.
Air Valve/
Stem
To House
1 in. Inlet Elbow
Connect pump to well
as shown. Connect 1 in.
Air pressure in the tank must be 2 PSI lower than
pipe (not included) to the
the "cut-in" of the pressure switch. Pump has
pump discharge opening.
a 20/40 PSI pressure switch, so tank pressure
Connect 1-1/4 in. pipe
must be set at 18 PSI. Check pressure with a tire
(not included) to the pump
gauge (not included) and add or subtract air as
suction opening.
needed.
Pressure Gauge or
Discharge tee plug
Vent plug
c. Check to be sure water in the cavity
of pump stays constant. If water level
goes down, it could indicate a leak in
the foot valve, check valve, or suction
pipe. If water remains constant, wrap
the pressure gauge or discharge tee
plug, and vent plug threads with thread
tape, and thread into pump. Tighten with
wrench (not included).
1 in.
Discharge Pipe
To Well
6
Connect the two wires
from the power supply
to the two open terminals on
the pressure switch. Connect
the green ground wire from
the power supply to the open
green ground screw in the
pressure switch.
Open
Terminals
Wire
Wire from
From
Power
Motor
Supply
Ground
Screws
Printed in China
SW1093 A

Publicidad

loading

Resumen de contenidos para STAR Water Systems SJR05S

  • Página 1 Power must NOT be connected. Air Valve/ 1 in. b. Pull selector plug out approximately 1/4-in. Stem MODEL #SJR05S Discharge Pipe c. Rotate plug to align arrow to 115 V or 230 V To House QUICK REFERENCE GUIDE. as desired.
  • Página 2 Válvula de Tubo de aire/vástago descarga de 1 pulg a. La alimentación NO debe c. Gire el tapón para alinear MODELO #SJR05S estar conectada. la flecha con 115 V o 230 A la casa V, según desee. GUÍA DE REFERENCIA RÁPIDA.