3. Installation and connection
3.1 Installation
Anti-vibration bases
1. Take out 4 Anti-vibration bases
2. Put them one by one on the bottom of
machine like the picture.
Draining jet
1. Install the draining jet under the
bottom panel
2. Connect with a water pipe to drain out
the water.
Note: Lift the heat pump to install the jet.
Never overturn the heat pump, it could
damage the compressor.
Water Inlet & outlet junction
1. Use the pipe tape to connect the
water Inlet & outlet junction onto the
heat pump
2. Install the two joints like the picture
shows
3. Screw them onto the water Inlet &
outlet junction
Mains Cable wiring
1. Open the cover of the electric box
inside the machine
2. Connect the cables in the correct
terminal according to electric diagram.
52