3.2 Heat pump location
The unit will work properly in any desired location as long as the following three items are present:
1. Fresh air
The unit may be installed in virtually any outdoor location as long as the specified minimum distances to other objects
are maintained (see drawing below). Please consult your installer for installation with an indoor pool. Installation in a
windy location does not present any problem at all, unlike the situation with a gas heater (including pilot flame
problems).
ATTENTION: Never install the unit in a closed room with a limited air volume in which the air expelled from the unit will
be reused, or close to shrubbery that could block the air inlet. Such locations impair the continuous supply of fresh air,
resulting in reduced efficiency and possibly preventing sufficient heat output.
See the drawing below for minimum dimensions.
Model
INVERBOOST 075P
INVERBOOST 095P
INVERBOOST 125P
INVERBOOST 145P
INVERBOOST 165P
INVERBOOST 215P
INVERBOOST 255P
INVERBOOST 305P
INVERBOOST 305PT
2. Electricity
Recommended minimum installation distance
A
B
(mm)
(mm)
300
1500
300
1500
300
1500
300
1500
300
1500
300
1500
300
1500
500
2000
500
2000
3. Swimming pool filters
C
D
(mm)
(mm)
300
600
300
600
300
600
300
600
300
600
300
600
300
600
500
800
500
800
54
Recommended distance for
special cases
B
Reserve
E
space to
(mm)
operate
controller
600
1500
600
1500
600
1500
600
1500
600
1500
600
1500
800
1500
800
2000
800
2000
B
Reserve
space for
maintenance
1500
1500
1500
1500
1500
1500
1500
2000
2000