TECHNICAL PROBLEMS
CIRCUMSTANCE
Machine doesn't stop
Audio level of the call isn't
correct
REGULATOR TECHNICAL PROBLEMAS
CIRCUMSTANCE
Starter does not start, no
fault displayed
Starter does not start, but
faults displayed
SYMPTOM
If it is the motor
If it is the sound
, motor and
lights
The acustic call is too loud
Acoustic call doesn't exist
Check that the run command input(s) have been actuated in accordance with the chosen
The cause of the fault must be removed before resetting
All faults can be resert by switching the drive off then on again
FAULT
OCF
Overcurrent
SCF
Motor short-circuit, insulation
fault
InF
Internal fault
CFF
Configuration fault
SOF
Overspeed
OHF
Drive overload
OLF
Motor overload
OSF
Overvoltage
ObF
Overvoltage during deceleration
PHF
Line phase failure
USF
Undervoltage
CrF
Charging circuit
CAUSE
Check triac and optotricac,
could be crossed
Timer of the sound-timer faulty
Parameter wrong regulated
Parameter wrong regulated
REPARATION
control mode
REMEDY
Ramp too short, check the settings
Mechanical locking, check the state of the instrument
Inertia or load too high, consult technical service
Check the cables connecting the drive to the motor, and the
insulation of the motor
Check the environment (electromagnetic compatibility)
Replace the drive
Return the factory settings or call up the backup
configuration, if it is valid
Inestability, check the motor, gain and stability parameters
Driving load too high, c
Check the motor load, the drive ventilation and the
environment. Wait for the drive to cool before restarting
Check the setting of the motor thermal protection, check the
motor load. Wait for the drive to cool before restarting
Check the line voltage
Bracking too harsh or driving load. Increase the deceleration
time, add a bracking resistor if necessary or consult the
technical service
This protection only operates with the drive on load
Check the power connection and the fuses
ResetConsult the technical service
Check the voltage and the voltage parameter
Replace the drive
REPAIR
Replace them
Graduate or consult technical
service
Consult paragraph 4, program
parameters
Consult paragraph 4, program
parameters
onsult technical service