EN
Troubleshooting
A qualified technician must carry out repairs if required.
Fault
The unit is not
working
Appliance does
not reach set
temperature, or slow
to heat up
Appliance heats up
but indicator light
does not come on
Heating indicator
light comes on but
appliance does not
heat up
No power
Oil overheats or starts
to smoke
Compliance
The WEEE logo on this product or its documentation indicates that the product must not
be disposed of as household waste. To help prevent possible harm to human health and/or
the environment, the product must be disposed of in an approved and environmentally safe
recycling process. For further information on how to dispose of this product correctly, contact
the product supplier, or the local authority responsible for waste disposal in your area.
Buffalo parts have undergone strict product testing in order to comply with
regulatory standards and specifications set by international, independent,
and federal authorities.
Buffalo products have been approved to carry the following symbol:
All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic,
mechanical, photocopying, recording or otherwise, without the prior written permission of Buffalo.
Every effort is made to ensure all details are correct at the time of going to press, however, Buffalo reserves the right to
8
CU476-CU477_ML_A5_v2_20240305.indb 8
CU476-CU477_ML_A5_v2_20240305.indb 8
Probable Cause
The unit is not switched on
Lead is damaged
Mains power supply fault
Faulty thermostat
Faulty heating element
Build-up of fat on heating
element
Indicator light has expired
Faulty thermostat
Faulty heating element
Thermostat set incorrectly
Thermal cut-out activated
Thermostat damaged
change specifications without notice.
Solution
Check the residual current relay and the
overcurrent fuse in the power supply line and
switch on
Replace lead
Check mains power supply
Consult a qualified technician
Consult a qualified technician
Clean the appliance
Consult a qualified technician
Consult a qualified technician
Consult a qualified technician
Check thermostat
Please check your machine is safe with no obvious
damage and then press the re-set switch
Switch Off immediately. Consult a qualified
technician
2024/3/5 11:32