Descargar Imprimir esta página

Levenhuk Wezzer PRO LP310 Guia Del Usuario página 12

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 53
Alarm setting order: setting the time, setting the upper thresholds for indoor temperature and humidity,
setting the upper thresholds for outdoor temperature and humidity, setting the upper threshold for wind gusts,
setting the upper threshold for precipitation, setting the lower thresholds for indoor temperature
and humidity, setting the lower thresholds for temperature and outdoor humidity.
Pressing MODE further will exit the alarm mode setup.
Max/Min mode
To view the maximum value, press the MODE button. To view the minimum value, press the MODE button
again.
To clear the maximum/minimum values, hold the MODE button while the value you want to clear is displayed.
In this mode, use the following buttons:
TEMP/+: maximum/minimum values for wind chill index, dew point, heat index and outdoor temperature.
WIND/−: maximum wind gusts, wind speed.
RAIN/PRE: maximum hourly precipitation, rain intensity.
RAIN/PRE (2 sec): enter pressure display mode, then RAIN/PRE to switch between relative and absolute
pressure.
To return to normal mode, press LIGHT.
Calibration mode
In outdoor temperature viewing mode, hold TEMP/+ for 5 seconds to re-register the sensor.
In the thermo-hygrometer sensor display mode on channels 1−8, press and hold TEMP/+ for 5 seconds
to re-register the current sensor on the channel.
In circular display mode, press and hold the TEMP/+ button for 5 seconds to re-register the sensor array
and sensors on channels 1−8.
Backlight controls
Press LIGHT for 2 seconds to wake up Wi-Fi from sleep mode. The display will enter WAK mode,
indicating Wi-Fi power saving when running on battery power.
The backlight can only be permanently switched on when the display console
is powered with the USB cable.
Press LIGHT to change brightness (high, medium, low, off).
While on battery power, press any button to activate the backlight
for 15 seconds.
Trend arrow indicators
The temperature, humidity and pressure change indicator shows the change in these values over a three-hour
update period.
Value rising:
Value falling:
Value steady:
Wireless signal strength indicator
The wireless signal strength indicator shows the reception quality. If the signal is stable, the indicator shows
4 bars. If the signal is lost once, the indicator shows 3 bars.
12

Publicidad

loading

Este manual también es adecuado para:

82931