3. Remove the nozzle by turning 9-32" (7 mm) nut driver
counter clockwise.
4. Install the injectors supplied with this appliances in the
appropriate burner. The injectors have small number
stamped on the side, this number codes the orifice diameter
and its correct burner location (see figure of the paragraph
"Injectors position").
5. Turn clockwise to tighten (tighten to a torque of 15 to 20
inch-lbs)
6. Replace all parts following the reverse order paying
attention to the correct placement of the burner.
6 - Conversion for LP or NG Gas
7. Save the injectors removed from the appliances for future
use.
Proceed to Pressure Regulator Conversion noting the
LP / Propane position to complete the conversion.
After replacing the injectors adjust the burner flame (see Low
Flame Adjustment paragraph).
Check the appearance of each burner's flame at HILO settings,
if the flame appears too large or too small make sure that all
steps were completed correctly.
Converting Appliances for Use with NG
Gas
If this appliance should be converted for use with gas NG
(natural gas), each of the following modifications must be
performed.
1. Convert the pressure regulator to NG position as per the
section "Pressure Regulator Conversion".
2. Replace all injectors following the step described on the
previous pages, observe the number stamped on the side,
this number corresponds to the orifice diameter and its
correct burner location (refer to the illustrations in section:
"Injectors Position").
3. Adjust the burner flame (see Low Flame Adjustment section).
Check the appearance of each burner's flame at HI - LO
settings, if the flame appears too large or too small make sure
that all steps were completed correctly.
EN
19