Descargar Imprimir esta página

Fulgor Milano SOFIA 30" Instrucciones Para La Instalación página 24

Ocultar thumbs Ver también para SOFIA 30":

Publicidad

Idiomas disponibles

Idiomas disponibles

6 - Conversion for LP or NG Gas
EN
Pressure regulator conversion
The appliances is designed for use with NG gas or LP gas. The
gas pressure regulator is supplied. It must be installed in the
gas supply line ahead of the manifold entrance.
It is pre-set for use with the gas as indicated on the appliance
label supplied with the appliance. For use with different gas
the appliance must be converted.
For the pressure regulator conversion follow the
instructions below:
• Disconnect all electrical power, at the main circuit breaker
or fuse box.
• Shut off the gas supply to the cooktop by closing the manual
shut-off valve.
• Adjust the pressure regulator, by following the instruction
(see figure)
1. Unscrew the regulator cap
2. Unscrew the plastic conversion plug from the cap turn
over and screw back (wide section away from cap for
LP and against cap for NG) see figures below.
3. Replace the regulator cap ensuring gasket is in place.
20
PRESSURE REGULATOR CONVERSION
NG POSITION
PLUG
NG
Before replacing the regulator cap, check if the position
of plug is suitable for the gas
CAP
GASKET
LP/PROPANE POSITION
PRESSURE REGULATOR
LP

Publicidad

loading

Este manual también es adecuado para:

Sofia 36"Sofia 48"F6pgr364gs2