Descargar Imprimir esta página

Electrical Schematic - Jofel AA17050 Manual De Uso

Publicidad

Idiomas disponibles

Idiomas disponibles

Trouble shooting electrical schematic
If you discover the following circumstance, please inspection and handiing as following:
Problem
No air blows even if
hands are inserted
Machine works long
time after hands
drawn out, finally
shows E2
No hot wind
Airflow is too low
If the above actions do not work, turn off the power and the ground-fault circuit breaker, and call your dealer
to inspect and repair it if necessary. (Costs are as per agreement with the dealer).

Electrical schematic

Power
switch
Wiring terminal
blocks
Heating
fuse
10A
Power
Status
Power
indicator
Light
light
Extinguish
State
indicator
light
Always light
Sterilizatior
indicator
Light
light
Digital changes
E1
Timing
digital
E3
tube
E5
Check
• Do the display indicators
lights up?
• Is the power switch on?
• Are you putting your hands
all the way in?
• Any dirt or foreign body on
sensor?
• There is a Built-in heater in
the unit. Any dirt on heating
sensor?
• Fuse inside terminal box
blown?
• Is the speed button on low
level?
Control PCB
Common
mode choke
Filtering
capacitors
Reactor
Fuse
Switch transformer
Infra-red light
receiving PCB
Introductions
Power input normally
Don't work
Flashing light
Working
UV Emission platedisinfect
sterilization startwork after
machine power on (one hour),
thereafter once a day
Countdown work
Jump display
Motor fault, it can't start
normally
The voltage exceeds 15%
Machine temperatures
higherthan 80°C
• Turn the ground-fault circuit breaker on.
• Turn the powerswitch on.
• Put hands all the way in .
• Switch offthe power button, and then remove dirt
or foreign body on sensor after the power light
gone out. When finished, switch on power button.
• Is the ambient temperature higher than 20°C?
• Switch off power, remove front cover. There is a
terminal box inside. Take down the cover of
terminal box. Check the fuse inside box which is
blown or not.
• Put speed button on the high level.
Filtering
capacitors
Temperature
probe
Infra—red light
start PCB
Status
Introductions
Power not supply
Extinguish
Master board fuse blew out
Motor fault, it can't
start normally
Trick or working time
longer than 25s
Sterilization work has ended
Extinguish
UV Emission plate error
Indicate drying time finished
Trick or working time longer
E2
than 25 seconds
E4
The voltage lower than 15%
Master board temperatures
E6
higherthan 80ºC
E8
Fan fault
- 18 -
Action
motor
Thermal Circuit
Thermal protection
Breakers
Heaters
switchr
UV start PCB
Heating
Speed
switch
switch
Display PCB
Solution
Check the external power source,
close the power switch
Check motor connecting wires
and the rotor foreign material
Clear workspace foreign material,
restart to work
Turn off the power, re-power After LEDs
are off. Sterilization indicator is still not
lit. Please check the UV Emission plat
Clear workspace foreign material,
restart to work
Check the power supply circuit
Clear the foreign material of the air
inlet and air outlet
Check whether the Fan sensor
connect is loosen

Publicidad

loading

Este manual también es adecuado para:

Aa17550