7
SERVICE
Turn off hot and cold water
supplies before beginning.
If faucet drips, operate HANDLE several times from "off" to "on." Do not apply excessive force.
Clogged CARTRIDGE outlets or inlets may cause reduced flow.
• Remove INDEX BUTTON (1), loosen HANDLE SCREW (2) and remove HANDLE (3).
• Remove the HANDLE CAP (4). Unthread the PLASTIC NUT (5).
• Lift CARTRIDGE (6) off MANIFOLD (7).
• Clean MANIFOLD (7) and CARTRIDGE (6) ports.
• Place CARTRIDGE (6) onto MANIFOLD (7) and tighten MOUNTING SCREWS (5) alternately.
• Replace ESCUTCHEON CAP (4), HANDLE (3), tighten HANDLE SCREW (2) and install INDEX BUTTON (1).
Clogged AERATOR may cause reduced flow:
• Unthread the AERATOR (8) with a coin or flat head screwdriver and clean it of any debris.
• Allow water to run through the faucet with no aerator to flush the hoses.
• Reinstall AERATOR (8).
8
CARE INSTRUCTIONS
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL
CLOTH. DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH
CLEANERS, OR A CLOTH WITH A COARSE SURFACE.
6
3
1
2
7
5
4