Performance
Data Sheet
Smart Water Filtration
System
GSWF Cartridge
This system
has been tested according
to NSF/ANS142/53
for reduction
of the substances
listed below.
The concentration
of the indicated
substances
in water
entering
the system
was reduced
to a concentration
less than or equal to the permissible
limit
for water
leaving
the system,
as specified
in NSF/ANS142/53.
"
"700% safhty fbctors built in for unrnetered
usnge )
Parameter
Chlorine
T&O
Particulate**
USEPA
MCL
InfJuent
Average
1.845 mg/L
143,333 #/mL
Standard No. 42: Aesthetic Effects
Influent
Challenge
Effluent
Concentration
Average
Maximum
2.0mg/L_+10%
< 0.05mg/L
0.05mg/L
at leas110,000 particles/m[
29.83 #/mL
140 #/mL
% Reduction
Average
Minimum
> 97.29%
96.43%
99.98%
99.91%
Min. Required
Reduction
> 50%
> 85%
Parameter
Turbidity
Cysts
Lead at pH 6.5
Lead at pH 8.5
Lindane
Atrazine
USEPA
MCL
1 NTU***
99.95%Reduction
0.015 mg/L
0.015 mg/L
0.0002mg/L
0.003 mg/L
Influent
Average
10.3 NTU***
200,000 #/L
0.15 mg/L
0.14 mg/L
0.0216 mg/L
0.008 mg/L
Standard
No. 53: Health
Effects
Influent Challenge
Concentration
1+_1NTU***
Minimum 50,000 L
0.15 mg/L_+lO%
0.15 mg/L_+lO%
0.002 mg/L_+lO%
0.009 mg/L_+ 10%
Effluent
Average
0.106 NTU
0
< 0.001 mg/L
0.001 mg/L
i< 0.00002 mg/L
< 0.002 mg/L
Maximum
0.14 NTU
0
< 0.001 mg/L
0.003 mg/L
< 0.00002 mg/L
< 0.002 mg/L
% Reduction
Average
Minimum
98.97%
98.61%
> 99.99%
> 99.99%
> 99.33%
> 99.33%
> 99.29%
97.86%
99.07%
98.75%
> 76.12%
> 66.67%
Min. Required
Reduction
0.5 NTU
> 99.95%
0.010 mg/L
0.010 mg/L
0,0002 mg/L
0,003 mg/L
Tested using a flow rate of O,5 gpm; pressure
of 60 ps/g; pH of Z 5 + O,5; temp, of 68 _"+ 5_'F (20 _"_ 3 _'C)
* * Measurement
in Particles/ml,
Particles used were O,5-7 microns
* ** NTU Nephelometric
Turbidity units
Operating
Specifications
[] Capacity: certified for up to 750 gallons (2,838 I); up to six months
[] Pressure requirement:
40-120
psi (2.8-8.2 bar)
[] Temperature:
33-100°F
(0,6-38°C)
[] Flow rate: 0,5 gpm (1,9 Ipm)
General
Instaflation/Operation/Maintenance
Requirements
[] Flush new cartridge
at full flow for 3 minutes to purge out trapped
air,
[] Replace cartridge
when flow becomes too slow,
Special
Notices
[] Installation
instructions,
parts and service availability,
and standard
warranty
are included with the product when shipped,
[] This drinking
water system must be maintained
according
to manufacturer's
instructions,
including
replacement
of filter
cartridges,
[] Do not use with water that is microbiologically
unsafe or of unknown
quality without
adequate
disinfection
before or after
the system, Systems certified for cyst reduction
may be used on disinfected
water that may contain
filterable
cysts,
[] The contaminants
or other substances
removed
or reduced by this water treatment
system are not necessarily
in your water,
[] Check for compliance
with the state and local laws and regulations,
[] Note that while the testing
was performed
under standard
laboratory
conditions,
actual performance
may vary, Systems
must be installed
and operated
in accordance
with manufacturer's
recommended
procedures
and guidelines,
System
tested
and certified
by NSF International
against
Standard
42 for the reduction
of
chlorine,
taste and odor, particulate
Class I and Standard
53 for the reduction
of cyst, lead,
Lindane,
Atrazine
and turbidity,
Manufactured
for: General
Electric
Company,
Louisville,
KY 40225
]
36

Publicidad

loading