Parallel Outlets
Located just above the Ground Terminal, the generator's Parallel Outlets enable a user to run two FG2500iS generator's
simultaneously. This operation requires special cables. When operating parallel generators, the rated output is 4.0kVA and
the rated current is 33.3A/120VAC. For cables and instructions consult a FORD dealer for a PARALLEL OPERATION
C C C A A A B B B L L L E E E K K K I I I T T T . . .
WARNING!
Never connect generators that are different models.
Only connect this generator to another FG2500iS Standard Generator.
Only use a parallel operation cable kit designed to work with this Generator.
Fuel Cap
Turn counterclockwise to remove the fuel cap.
Ground Terminal
The generator's ground terminal must always be used to connect the
generator to a driven ground rod. Connect the ground terminal to the
driven ground rod with a 14 AWG (American Wire Gage) copper wire. The
wire connects to the terminal between the lock washer and nut. Tighten the
nut securely to ensure good connection. Grounding the generator protects
you from electric shock that results from a build up of static electricity or
undetected ground faults.
WARNING!
Only operate generator on a level surface.
Always connect the nut and ground terminal on the frame to an appropriate ground source.
CONTROL PANEL FUNCTIONS
Generator must be properly grounded to prevent electrocution.