INSTALLATION CLASS 3
TECHNICAL INFORMATION FOR THE INSTALLER
•
Use protective gloves for handling, preparing and installing the product.
•
This product can be embedded in a worktop 20 ÷ 40 mm thick.
•
If there is no oven beneath the hob, insert a separator panel that has a surface at least equal to the opening in the work surface. This panel must be positioned
at a maximum distance of 150 mm below the upper surface of the work surface but, in no case less than 20 mm from the bottom of the hob. In the case that
you intend to install an oven beneath the hob, make sure that it is equipped with a cooling system.
NOTE: The burner ame may be extinguished by an air ow, if the removable panel is not installed. The air ow may occur when you open or close the
cabinet door or drawer.
DIMENSIONS AND DISTANCES TO BE MAINTAINED
20-40 mm
NOTE: Kitchen cabinets adjacent to the appliance and taller than the top of the hob must be at least 200 mm from the edge of the hob.
Hoods must be installed according to their relative installation instruction manuals and at a minimum distance of 650 mm from the hob (see gure).
Place the wall cabinets adjacent to the hood at a minimum height of 420 mm from the hob (see gure).
If the hob is installed beneath a wall cabinet, the latter must be situated at a minimum of 700 mm above the hob.
ASSEMBLY
After having cleaned the perimeter surface, apply the supplied gasket to the hob as shown in the gure.
Position the hob in the worktop opening made respecting the dimensions indicated in the Instruction.
NOTE: the power supply cable must be long enough to permit its upward extraction.
To secure the hob, use the brackets (A) provided with it. Fit the brackets into the relevant bores shown by the arrow and
fasten them by means of their screws in accordance with the thickness of the worktop (see the following gures).
A
GAS CONNECTION
•
Connect elbow (A)* or (B)* supplied with to the hob inlet main pipe and interpose the washer (C) supplied, in compliance with
EN 549.
* Use elbow (A) for France and elbow (B) for all other destinations.
•
After connection to the gas supply, check for leaks with soapy water. Light up the burners and turn the knobs from maximum
position to minimum position to check ame stability.
ELECTRICAL CONNECTION
L
Ground cable
(yellow / green)
N
min. 55 mm
20 mm
20
30 mm
30
Min. 650 mm
Min. 600 mm
Min. 420 mm
Min. 200 mm
40 mm
40
C
C
A
C
B