DESCRIPTION OF THE PRODUCT
1
ELEMENTS OF THE COMPLETE INSTALLATION
INSTALLATION COMPONENTS:
1
Operator
2
Wall pushbutton
3
Control board
4
Photocells
5
Antenna
ELECTRICAL CABLING:
Element
A: Main power supply
B: plug-in receiver
C: Photocells (Tx / Rx)
D: Pushbutton
E: Operator / Limit switches
F: Antenna
Fig. 1
Elements of the complete installation
The safe and correct operation of the
installation is the responsibility of the installer.
Nº threads x section
2
SK110: 3x1.5 mm
2
SK130, SK135: 5x1.5 mm
2
3x0.5 mm
2
2
2x0.5 mm
/ 4x0.5mm
2
2x0.5 mm
2
2
4x1 mm
/ 4x0.5mm
Screened cable
For greater safety, Erreka recommends installing the
photocells (4).
Maximum length
30m
20m
30m
25m
20m
5m
SKY electromechanical operator