EN
An automatic self-check of the
main functions will be performed
at the start up. If the result is
positive, the stand-by menu on
the right-side picture will show
up.
Scroll the menu with the
top ▲and bottom ▼buttons to
select an option.
Confirm the option selection with
OK button.
MENU OPTIONS
WELDING
THROUGHT
CODE READING
below
WELDING THROUGHT MANUAL
INPUT OF BAR CODE on page
15
WELDING THROUGHT MANUAL
INPUT OF WELDING VOLTAGE
AND TIME
on page 15
PRINTOUT
AND
CONNECTION
on page 16
SETUP and UTILITY
below
BAR CODES TYPES
Bar codes (both welding and traceability) are attached to the
coupler. The data contained in the bar codes are stored in the
machine's memory once the welding procedure has started.
Welding data, including the barcode data, can be either
printed or downloaded into a USB drive. Additional parameters
can also be stored in each welding.
WELDING BAR CODE:
The welding barcode contains mainly data related to the
welding procedure (e.g. welding voltage and time, cooling
time, ...).
TRACEABILTY BAR CODE:
The traceability barcode contains mainly data related to the
coupler's manufacturing (e.g. type, brand, material, diameter,
SDR, production batch, ...).
Note: the traceability reading must be enabled to work.
14
BAR
USB
SETUP and UTILITY
Push OK to enter.
Scroll the menu with the
top ▲ and bottom ▼ buttons to
select an option (highlighted).
Push OK to confirm.
TRACEABILITY and NOTE
Traceability
It allows to read the traceability
barcode on the coupler.
This option is enabled (ON) or
disabled (OFF).
Use top ▲ and bottom ▼ buttons
to switch.
Push OK ► button to confirm.
Note
It allows to add some text to be
stored in memory before the
welding starts.
This option is enabled (ON) or
disabled (OFF).
Use top ▲ and bottom ▼ buttons
to switch.
Push OK button to confirm.
The Note value will show up in the
welding reports.
INFORMATION
It shows some product features:
•
Overhaul (next service date)
e.g. 11/2022
•
Serial number e.g. 203400256
•
Stored weldings
•
Firmware version.
Push STOP to exit.
OTHER FUNCTIONS
It allows to setup some specific
parameters
through
numbers (codes).
Use ▲ and ▼ buttons to change
the digit value and OK ►button to
move to the next digit.
Codes available to the user are on
page 16.
OPTIONS
Traceability
Note
Information
Other functions
Contrast
Traceability [or Note]
ENABLED
Information
11/2022
203400256
120/500
V 11.2
4-digit
Other functions
0000
OFF
ON