2. TECHNICAL DATA
Model
Mains voltage / Frequency
(V / Hz)
Nominal performance (Watts)
Protection type (IP)
Suction port
Pressure port
Max. flow rate (Qmax)
(l/h)
(1)
Max. pressure
(bar)
(3)
Max. delivery height
(Hmax)
(m)
(1)
Max. suction height (m)
Vessel material
Tank volume (l)
Vessel type
Max. operating pressure (b)
Max. size of the solids being
pumped (mm)
Min. fluid temperature (°C)
Max. fluid temperature
(Tmax) (°C)
Length of connection cable (m)
Cable type
Weight (net) (kg)
Guaranteed sound power level
(LWA)
(dB)
(2)
Measured sound power level
(LWA)
(dB)
(2)
ACS
Dimensions (L x D x H) (mm)
1) The values were determined with free, unreduced in- an
outlet.
2) Noise emission values obtained according to the EN 12639
regulation. Measurement method according to EN ISO
3744.
Preset of the pressure switch
Cut-in pressure (bar)
Cut-out pressure (bar)
3) The theoretically achievable pressure of the pump unit of the
domestic water supply can reach the value specified under
"Max pressure". Consult a qualified specialist, to adapt the
pressure circuit to your requirements if necessary, see also
the chapter "Setting the pressure switch".
3. RANGE OF USE
The typical areas of use of booster sets include:
Automatic domestic water supply with grey water
from wells and cisterns, automated irrigation of
gardens and garden beds and sprinkling, pressure
boosting within the domestic water supply system.
The device is not suited for use in swimming pools.
GC-1100F/50B
This product is intended for private use in the home
area and not for commercial or industrial purposes or
220-240/50
for continuous circulating.
1100
x4
M26/34
M26/34
temperatures of the liquids to be discharged stated
4500
in the technical data.
4,5
4. SCOPE OF DELIVERY
45
The scope of the delivery of this product includes :
7
one booster set with a connection cord, one
operating manual.
STEEL
50
Please verify that the scope of delivery is complete.
Depending on the purpose of the application,
BLADDER
additional accessories may be necessary (see
-
Chapter 7, 8 and 9).
1
If possible, keep the packing until the warranty
period has expired. Please dispose of the packing
5
materials in an environmental-friendly manner.
35
5. INSTALLATION
10
5.1. GENERAL INSTALLATION INFORMATION
H07RN-F
20
-
-
NO
and the entire connection system have to be
730 x 410 x 645
protected from frost and other climatic influences.
All connection lines have to be perfectly tight since
leaking lines may affect the performance of the
pump and cause considerable damage. Therefore,
please use Teflon tape to seal the contact surfaces
between the threaded sections of the lines and
2
the connection with the pump. This use of sealing
3,5
material such as Teflon tape is the only way to ensure
an airtight assembly.
When tightening threaded connections, please do
not apply excessive force which may cause damage.
When laying the connection pipes, you should make
sure that the pump is not exposed to any form of
weight, vibration or tension. Moreover, the connection
lines must not contain any kinks or an adverse slope.
Please observe the illustrations, too, which are
contained as an attachment at the end of the present
operating instructions. The numeric and other details
included in brackets below refer to these illustrations.
The pump is not suited to discharge
saltwater, faeces, inflammable, etching,
explosive or other hazardous liquids.
Please observe the max. and min.
During the entire process of installation, the
device must not be connected to the
electrical mains.
The pump should be installed in a dry place
with an ambient temperature not to exceed
40 °C and not to fall below 5 °C. The pump
When installing the device, please make
sure that the motor is sufficiently ventilated.