OVEN INSTRUCTIONS
The following considerations must be taken into account for the correct operation of the oven:
- The oven needs a warm-up period of approximately one hour, during this hour the woodstove
must be at full load. We ignite the stove with fine, dry wood splinters. During the one hour
heating period, at least two reloads of approximately 2 kg of wood should be made, keeping
the air inlet regulation open to the maximum.
- Once the heating is finished, we can place the food in the oven, during the cooking process
we must maintain an operating regime at nominal power, it is recommended to reload the
wood every 30-40 minutes using two logs of approximately 2 kg of mass and keeping the air
inlet at maximum.
- It is very important to keep the oven door closed to avoid a sudden loss of temperature. If
it is necessary to open the door for any operation, remember to do it in the shortest possible
time.
- Height
...................................................
- Width
...................................................
- Depth
....................................................
- Weight
......................................................
- Firewood entrance
- Smoke outlet
.........................
- Iron sheet body of 6 3 mm.
- Cast iron grill
- Paint, resistant up to 800 °C
- Vitro-ceramic glass, 750 °C
- Firewood up to 50 cm long
- Nominal heat output
- Energy efficiency
- CO emission
........................................
- Minimum flue draught for
nominal heat output
- Flue gas mass flow
- Flue gas temperature
- Distance to adjacent
combustible materials
- Heating volume (aprox.)
MEASUREMENTS AND CHARACTERISTICS
1326 mm
646 mm
483 mm
210 Kg
485 x 261 mm
......
150-153 mm
+
6,7 kW
...................
80.7 %
................................
0.10 %
12 Pa
.......................
8,5 g/s
......................
236 °C
..................
- Side....60 cm
- Rear wall....10 cm
-Front......60 cm
210 m
3
..........
DIN EN 13240: 2001 & A2: 2004
& AC: 2007
"YUCCA" WOODSTOVE
FREESTANDING ROOMHEATER FIRED BY SOLID FUEL
CERTIFICATE Nº ......................39-11540-T-4
DECLARATION OF PERFORMANCE.....................11014/11015
NOTIFIED BODY ..............................................1015
Thermal output
..........................................................
Energy efficiency
..........................................................
Emission of CO in combustion products
Flue gas temperature
Distance to adjacent combustible materials
- Side....60 cm
- Rear wall....10 cm
-Front......60 cm
Dust concentration at 13% O2 ........
..............
Fuel types
Firewood and briquetted wood
7
Mod.
YUCCA
P . I .
C A M P O L L A N O
AVDA. 5ª NORTE, 13-15
02007 ALBACETE -SPAIN
..............................
6,7 kW
80.7 %
0.10 %
...
236 °C
...........................................
30 mg/Nm
18
3