GROUNDING INSTRUCTIONS
• This range hood must be grounded. In the event of an electri-
cal short circuit, grounding reduces the risk of electric shock
by providing an escape wire for the electric current.
• This range hood is equipped with a cord having a grounding
wire with a grounding plug. The plug must be plugged into an
outlet that is properly installed and grounded.
WARNING: Improper grounding can result in a risk of electric
shock.
Consult a qualified electrician if the grounding instructions are
not completely understood, or if doubt exists as to whether
the range hood is properly grounded.
Do not use an extension cord. If the power supply cord is too short,
have a qualified electrician install an outlet near the range hood.
SAVE THESE INSTRUCTIONS
Installation Instructions
Prepare location
It is recommended that the vent system be installed before the
range hood is installed.
Before making cutouts, make sure there is proper clearance
within the ceiling or wall for vent fittings.
Making the cutout to the bottom of the cabinet may be
easier to do prior to mounting the cabinet to the wall.
1
Disconnect power.
2
Determine which venting method to use: roof, wall, or non
vented.
3
Select a flat surface for assembling the range hood. Place
covering over that surface.
I WARNING
EXCESSIVE WEIGHT HAZARD
USE TWO OR MORE PEOPLE TO MOVE AND INSTALL
RANGE HOOD.
FAILURE TO DO SO CAN RESULT IN BACK OR OTHER INJURY.
4
Using 2 or more people, lift range hood onto covered
surface.
Range hood cabinet cutout
1
Use a saber saw or keyhole saw to cut out the cabinet
bottom inside the cabinet frame.
NOTE: Frameless type cabinets require .7" (1.9 cm) front lip in
the cabinet bottom. A .7" (1.9 cm) thick filler strip (not supplied)
may be required for some types of cabinets. (See Step 3 in
the "Install Range Hood" section).
Cut out dimensions
Without spacers
0.5"
(1.27 cm)
0.7"
(1.9 cm)
0.7"
(1.9 cm)
0.5"
(1.27 cm)
10.9"
(27.8cm)
28.4"
(72.2 cm)
With 1 or 2 spacers
0.5"
(1.27 cm
)
1 spacer
11.4"
(29cm)
(72.2 cm)
A.
Bottom of cabinet cutout
2
Complete cabinet preparation following the instructions
for your type of venting. Determine venting cutout loca-
tions and cut out vent openings in the cabinets, walls and/
or soffit.
Venting outside through the roof
1
Measure and mark the lines as shown. Use a saber saw or
keyhole saw to cut an opening through the top of the cabinet
and the roof for the vent.
Cutout Chart
Cabinet Height
Hole Shape and Size
12" (30.5 cm)
A 8.2" wide x 6.2" deep (21 cm x 15.9 cm)
rectangular opening in the cabinet top is
required for damper transition clearance.
A
C
D
A.
Cutout
B.
8.2" (21 cm) x 6.2" (15.9 cm)*
C.
7.8" (20 cm) centerline to cabinet front
D.
Centerline of the cabinet
E.
4.1" (10.6 cm)
F.
3.2" (8.3 cm) center to cabinet front
G.
Ø (4 cm)*
0.7"
(1.9 cm)
0.5"
(1.27 cm)
2 spacers
11.9"
(30.3cm)
28.4"
B*
G*
F
E
A
7

Publicidad

loading

Este manual también es adecuado para:

Eas328ss