Programs
Menu item
Description
[EN]
[DE]
30
Select covered urinal operation.
[CoverOps]
Program switches operation
[Deckel-UR]
with the covered urinals on or
off
31
Enable manual flush.
[ManFlshEn]
Switches on the second
[FreiManSp]
sensor, which the user can use
to release a flush ahead of time
with his hand
32
Select interval flush.
[IntFlush]
Starts the interval flush
[IntervSp]
program. The control flushes
automatically at the interval
dictated by the entered value
54 [IntervalT] [IntervalZ] for the
duration of the entered value
53 [IntFlushT] [IntervSpZ] after
the last use
33
Select power-on flush.
[PowOnFlsh]
If the mains voltage is on, a
[NetzEinSp]
flush is released by the control
34
Select dynamic flush.
[DynFlush]
Flush control adapts itself to the
[DynamSpül]
user frequency
35
Select pre-flush.
[PreFlush]
Flushes for 3 s on entry into the
[Vorspülng]
detection range if the urinal has
not been used for at least 10
min
36
Select follow-up flush.
[FollwFlsh]
Flushes once at the end of the
[FolgeSpül]
entered value 52 [DelFollwF]
[FolgVerzö] after the last use
37
Select post flush.
[PostFlush]
Flushes for 2 s, 3 s after a main
[NachSpül]
flush
38
Select attendance flush.
[AttndFlsh]
Flushes as long as a user is
[BeglSpül]
detected (60 s max.)
39
Activate hybrid mode
[HybridMod]
[HybridMod]
40
Activate purging flush
[PurgFlsh]
[PurgFlsh]
1)
A detailed description of the interval modes can be found on the next page.
Application
When the open cover of the
covered urinal blocks the
sensor
Manual touchless flush during
use
1)
a) Refilling the trap if the
frequency of use is low
b) Flushing out of stagnant
water (to prevent stagnation)
a) Releasing the central flush
b) Function confirmation
Shortening the flush time for
high user frequencies (e.g. in a
sports stadium)
Wets the urinal ceramic before
use to reduce deposits
a) Flushing the urinal ceramic
b) Filling up the trap
Filling up the trap
a) Thorough flushing
b) Background noise
High water consumption
1)
Waterless operation with
periodic flush for minimal water
consumption
1)
Flush deposits in the drainage
system. Deposits may
accumulate significantly in
hybrid mode or if flush times are
short
Service
Adjustment
Factory
range
setting
On = [ON]
Off = [OFF]
Off = [OFF]
On = [ON]
Off = [OFF]
Off = [OFF]
On = [ON]
On = [ON]
Off = [OFF]
On = [ON]
On = [ON]
Off = [OFF]
On = [ON]
On = [ON]
Off = [OFF]
On = [ON]
Off = [OFF]
Off = [OFF]
On = [ON]
Off = [OFF]
Off = [OFF]
On = [ON]
Off = [OFF]
Off = [OFF]
On = [ON]
Off = [OFF]
Off = [OFF]
Off = [0]
Off = [0]
Use = [1]
Time = [2]
On = [ON]
Off = [OFF]
Off = [OFF]