Descargar Imprimir esta página

Sears CRAFTSMAN 919.167462 Manual Del Propietário página 14

Publicidad

Idiomas disponibles

Idiomas disponibles

5.
Run the compressor for 15
minutes. Make sure the drain
valve is open and there is
minimal air pressure build-up in
tank.
6.
After 15 minutes, close the drain
valve (clockwise). The air receiver
will fill to "cut-out" pressure and
the motor will stop.
The compressor is now ready for use.
Before Each Start-Up:
1.
Place On/Auto/Off lever to
"OFF".
2.
Pull regulator knob out, turn
counter-clockwise until it stops.
Push knob in to lock in place.
3.
Attach hose and accessories.
NOTE: The hose or accessory
will require a quick connect plug
if the air outlet is equipped with a
quick connect.
A01198
causes a hazardous risk of bursting.
Check the manufacturer's maximum
pressure rating for air tools and
accessories. The regulator outlet
pressure must never exceed the
maximum pressure rating.
How to Start:
1.
Turn the On/Auto/Off lever to
"AUTO" and allow tank pressure
to build. Motor will stop when
tank pressure reaches "cut-out"
pressure.
2.
Pull the regulator knob out and
turn clockwise to increase
pressure. When the desired
pressure is reached push knob in
to lock in place.
The compressor is ready for use.
14- ENG
Risk of Bursting. Too
much air pressure

Publicidad

loading

Este manual también es adecuado para:

Craftsman 919-16746-ca