4 - PRODUCT INSTALLATION
4.1 - Installation
Before starting the installation, make sure that the product is intact
and that the packaging contains all the components shown.
Make sure that the mounting area is compatible with the overall
dimensions (Fig.1).
Check the allowed opening angle according to the fixing points of the
brackets in Fig.3 and in the diagram in Fig.2.
Fig.4 is an example of a typical system:
- Operators (1)
- Photocells (2)
- Posts for photocells (3)
- Flashing light with integrated aerial (4)
- Key or digital switch (5)
Mounting the motor bracket to the pillar
Center the pillar bracket fissando previously traced by fixing the
bracket using suitable screws and washers (not supplied) (Fig.1).
4.2 - Adjusting the limit switch (230 Vac version)
Unscrew the cover screws.
Loosen the screws to adjust the electrical limit switches until you are
4.3 - Electrical connections
Insert the supply cable to the terminal. Connect the wires of the supply cable to the terminal following the electrical drawing in Fig. 5.
4.4 - Mechanical and electronic connections of the second motor
In case of installation of the second motor, follow the above
mentioned instructions for the mechanical mounting, for the
Fasten the motor to the pillar bracket with the screws and nuts
supplied. During this phase, make sure that the motor is perfectly
aligned.
ATTENTION: an off-axis mounting can cause malfunctioning
and damage the automation system.
Mounting the motor bracket
Move the gate leaf up to the maximum opening position.
Release the gearmotor.
Place the arm close to the leaf and lay on the leaf the gate bracket;
holding with one hand the bracket in contact with the leaf, try to
make a complete opening and closing movement.
Fasten the gate bracket to the leaf with suited screws (not sup-
plied).
Fasten the motor arm to the bracket.
Important: make sure that the bracket and the gate arm are
perfectly aligned.
ATTENTION: a not aligned mounting can cause malfunctioning
and damage the automation system.
able to scroll.
Screw in the desired position.
electrical connections refer to the Fig.5.
EN
11