INSTALLATION
Cleaning, care and maintenance
6.
Cleaning, care and maintenance
DANGER: Electrocution
Before cleaning, make sure the power has been turned
off at the circuit breaker panel and that the heating
element of the heater is cool.
Clean the exterior of the heater when cold with ordinary cleaning
products. Avoid abrasive or corrosive cleaning products.
If a pale brownish discoloration appears on the heater casing,
wipe this off as soon as possible with a damp cloth.
MATERIAL LOSSES:
!
Never spray cleaning spray into the air slot.
Dust filter cleaning
- Clean the dust filter at regular intervals. The dust filter can
be pulled out from either side of the heater.
You may need to detach the heater from the wall mounting
bracket beforehand (See 11.1, "Wall mounting", pg. 6).
7.
Storage
When not in use, keep the heater in a dry place.
8.
Troubleshooting
Problem
Cause
The heater does not
The dust filter is heavily
deliver the required
clogged.
heating output.
The heater does not
The temperature has
heat up.
been set too low on the
heater.
Fuse or safety switch has
blown/tripped.
Overheating. High limit
safety cut-out has re-
sponded.
Fuse has blown.
If you cannot fix the problem, notify your qualified contractor. To
facilitate and speed up your request, provide the number from the
type plate (000000-0000-000000).
SAVE THESE INSTRUCTIONS
www.stiebel-eltron-usa.com
INSTALLATION
9.
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the heater.
9.1
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the heater
are used.
9.2
- Install the heater in such a way that control equipment can-
- All electrical connection and installation work must be car-
- Only mount the heater on a vertical wall that is tempera-
- Maintain minimum clearances to adjacent surfaces (See 14.2,
- Ensure wiring to the heater is of adequate gauge.
- Mount the heater no nearer than 4˝ (10 cm) from a wall
- Never install the heater directly below a wall socket.
- When installing the heating heater in rooms with a bath or
Solution
- Observe the type plate. The specified voltage must match the
Check and, if necessary,
clean the dust filter.
Check the temperature set
10. Heater description
on the heater.
The heater is a wall-mounted electric heater. It is particularly
Check the circuit breaker in
suitable for heating rooms, such as work rooms, kitchens, bath-
your distribution panel.
rooms, wash rooms etc.
Eliminate the cause (dirt or
obstructions at the air inlet
or outlet). The high limit
will reset automatically.
Heater cannot be restarted.
Contact Stiebel Eltron.
10.1 Standard delivery
The following are delivered with the heater:
- Wall mounting bracket
Safety
General safety instructions
Instructions, standards and regulations
NOTE:
Observe all applicable national and regional regula-
tions and instructions.
not be touched by a person in the bath or shower.
ried out in accordance with the rules of your local power
supply utility, and relevant national and local regulations.
ture-resistant to at least 194°F (90°C).
"Minimum clearances to hard surfaces", pg. 8).
socket.
shower, observe the safety zone in accordance with the de-
tails on the heater type plate.
mains voltage.
WARNING: Fire
A heater has hot and arcing or sparking parts inside.
Do not use it in areas where gasoline, paint or flam-
mable vapors or liquids are used or stored.
CK 150-1 / 200-2 Trend |
5